Diagnostics
7.2 Parameterization of the diagnostics
RF180C communication module
Operating Instructions, 12/2012, J31069-D0177-U001-A6-7618
51
Other communication module operating modes are indicated by the PRE, ERR, ACT, SF
and ON LEDs:
Table 7- 4
LED display for operating states
ON
BF
SF
PRE_1 ERR_1 ACT_1 PRE_2 ERR_2 ACT_2 Description
Off
Off
Off
Off
Off
Off
Off
Off
Off
Start-up active
On
On
On
On
On
On
On
On
On
LED test on start-up
(start PROFINET IO)
Off
Off
On
On
On
Off
On
On
Off
Internal fault
Off
Off
On
On
Off
On
On
Off
On
Checksum error of the firmware
Off
Off
On
Off
Slow
flashin
g
Off
Off
Slow
flashin
g
Off
Firmware update
(flashes with every described area)
7.2
Parameterization of the diagnostics
Faults are reported by PROFINET IO through the generation of alarms. Alarms are output
using OB82. The alarm data can be accessed using SFB 54.
Parameterizing possibilities
Description of the alarm messages:
●
None
An alarm will not be issued in the event of an error.
●
Hard errors
Alarms are generated in the case of the following events:
–
Hardware fault (memory test)
–
Firmware fault (checksum)
–
Break in connection to reader
An alarm is generated and the SF LED on the S7 CPU is activated.
●
Hard / soft errors
In contrast to hard errors, in this case, errors are also reported that arise during command
processing.
An alarm is generated. However the SF LED on the S7 CPU is activated.
An alarm is generated when an event occurs as well as when the event ceases.
Incoming alarm
An event occurs and triggers an alarm. The SF LED of the S7 CPU is set as parameterized.