background image

Settings for automatic operation with 2 heating periods 

24-hour operation  

 

24-hour operation with only one heating period (the 
heating period will automatically be generated from 
the current 24-hour program). 
Start of the first heating period, end of the last 
heating period, plus the currently adjusted comfort 
temperature setpoint.

 

Retrieving the default values 

Press the button behind the small opening for at 
least one second, thus resetting the user-specific 
and the “Permanent-self-learning operating mode” 
as well as display of flow temperature, outside 
temperature and d.h.w. setpoint to their default 
values (the heating engineer settings will not be 
changed). 
The clock starts at 12:00. 
When making a reset, all display fields will light up. 

Caution:

   If the controller is removed from its base 

 

for more than 60 seconds, an error 

 

message will appear on the display. 

 

When sliding the controller back to its 

 

base, the error message must disappear 

 

after 2 minutes at the latest. 

 

Without inserted batteries, reset 

 

functions correctly for a maximum  

 

of 15 seconds only after removing  

 REV23M 

 

from its base. 

 

Default values 
Factory settings for heating 

Operating mode

 

 

 

 

Start of continuous operation

 

00:00 00:00 00:00

End of continuous operations

 

24:00

 

24:00 24:00

Setpoint of comfort mode

 

19 °C

 

 

 

Setpoint of economy mode

 

 

16 °C

 

Setpoint frost protection

 

 

 

5 °C

 

Setpoint 

 

remote operation 

10 °C

 

CLICK

    

  

Ö

  

 

 

Ö

  

  

Ö

  

 

 

Ö

  

  

Ö

   

 

h

  

Ö

  

 

 

h

  

Ö

 

 

° C

  

 

Ö

 

 

  

Ö

 

 

h

  

Ö

 

 

h

  

Ö

 

 

° C

Ö

  

 

 

  

Ö

  

  

Ö

 

 

 

/

  

Ö

  

 

 

If no button is pressed for 20 seconds, the setting 
displayed will be accepted and the initial display 
restored.

 

  1. Press:  You access the menu level; 
 the

 clock 

flashes. 

  2. Roll: 

Twice toward the display; 

 menu 

 flashes. 

  3. Press:  You accept the menu; 

  

the

 day selection

 symbol    

  flashes. 

  4. Roll: 

Select the days, the working days, the 

 

weekend or the week. 

  5. Press:  You save the selection made;  
 

heating period

 

 flashes. 

  6. Press:  Accept 

heating period 1

 flashes. 

  7. Press:  You accept 

heating period

 

1

 

start time 

of heating period 1 flashes.  

  8. Roll: 

Set the 

start time

 of heating period 1. 

  9. Press:  You save the input;  

 end 

time 

of heating period 1 flashes. 

10. Roll: 

Set the 

end time

 of heating period 1. 

11. Press:  You save the input; 
 

setpoint 

of heating period 1 flashes.

 

12. Roll: 

Set the 

setpoint

 of heating period 1. 

13. Press:  You save the input; 

 

heating period 2

 flashes.

 

14. Press:  You accept 

heating period 2

;

 

 start 

time 

of heating period 2 flashes.

 

15. Roll: 

Set the 

start time

 of heating period 2. 

16. Press:  You save the input;

 

 end 

time 

of heating period 2 flashes. 

17. Roll: 

Set the 

end time

 of heating period 2.

 

18. Press:  You save the input;

 

 setpoint 

of heating period 2 flashes.

 

19. Roll: 

Set the 

setpoint

 of heating period 2. 

20. Press the Esc button to return to the 

heating 

 

periods

 menu: 

 Menu 

item 

heating periods

 

 

 flashes.

 

21. Roll: 

Toward the display or away from it to 

 

menu item;  

 

 

or heating periods  

 

 

 

(change not necessarily required; press 
the Esc button several times to leave the 
menu level in several steps, thus 
returning to the initial display). 

 

Setpoint 

 

absence

 

12 °C

 

 

 

Operating mode 

 

Selected periods 

 

Settings for automatic operation with 1 or 3 heating periods

 

Start of period 1 

07:00

 

06:00 06:00

End of period 1 

23:00

 

08:00 08:00

The procedure to be followed is the same as that for automatic operation with 2 heating periods the only 
difference being that, in addition, a setpoint for heating period 3 can be entered (standard setting 21 °C). 

Start of period 2 

 

17:00 11:00

 

 

End of period 2 

 

22:00 13:00

 

 

Start of period 3 

 

17:00

End of period 3

 

 

 

22:00

Absence / holidays  

 

Setpoint of period 1

 

19 °C

 

19 °C 19 °C

Setpoint of period 2

 

 

20 °C 20 °C

Setpoint of period 3

 

 

 

21 °C

Setpoints 

 

and 

 

See above

 

 
 

Changing the batteries         
2 Alkaline batteries type AA 1.5 V 

CLICK

    

  

Ö

 

 

  

Ö

  

  

Ö

 

 

  

Ö

  

° C

 

 

 

Ö

  

  

Ö

  

 

 

If no button is pressed for 20 seconds, the setting 
displayed will be accepted and the initial display will 
appear again.

 

1. Press:   You access the menu level; 
 the 

clock

 flashes. 

2. Roll: 

Away from the display,  

 menu 

  

 

flashes.

 

3. Press:   Accept 

 

;

  

 

symbol

 

 

flashes.

 

4. Roll: 

Set the start (weekday) of your 

 absence. 
5. Press:   You save the input; 
 

the number of days flash. 

6. Roll: 

Set the duration of your absence; 

 

number of days (max. 99) 

7. Press: 

You save the input; 

 setpoint 

 flashes. 

8. Roll: 

Set the temperature. 

9. Press the Esc button to return to the menu level; 
 the 

clock

 flashes. 

 

 

(change not necessarily required;  press 

 

  the Esc button again to return to the  

  

initial 

 

display). 

When this symbol appears, the batteries must be 
replaced within 3 months. 

1.  

Remove controller from its base. 

2.   Open battery compartment at the rear and 
 replace 

the 

batteries. 

3.  Close battery compartment and replace the 
 controller. 

Note:

  

When changing the batteries, the current data are 
maintained for a maximum of one minute.

 

 

Siemens SBT / HVAC Products 

CE1B2266en 

02.07.2003 

 

Reviews: