Siemens Building Technologies

Room Units QAA53, QAA73

CE1Q2282en

HVAC Products

04.09.2001

The room units are designed for the OEM market. They are supplied directly to the
boiler manufacturer and enhance the functionality and the level of control of small gas-
fired appliances with integrated boiler temperature controllers.

Functions

Q

AA73.110

Q

AA53.110

  Generation of the flow temperature setpoint

x x

  Pure room temperature control

x x

  Weather-compensated flow temperature control while giving consideration to

the building’s thermal dynamics

x

  Weather-compensated flow temperature control with room compensation

x

  Effect of room temperature deviation can be adjusted

x

  Optimum start / stop control

x

  ECO functions (24-hour limit switch, automatic summer / winter changeover)

x

 Quick setback

x x

  Room temperature switching differential for limiting the room temperature

x x

  Adjustable maximum limitation of the flow temperature (especially in

connection with floor heating systems)

x

  Limitation of the rate of increase of the flow temperature setpoint

x

  Frost protection for the building

x x

 Frost warning

x

  D.h.w. control with release and preselection of setpoint for the boiler controller

x

 Legionella function

x

  Integrated yearly clock with backup (minimum  12 hours)

x

  Integrated 24-hour clock with backup (minimum  12 hours)

x

  Operating levels based on ergonomic and functional considerations

x x

  Operating mode, setpoint adjustment and occupancy button

x x

  Every setting or change is displayed and thus acknowledged

x x

  Clear text display in a number of selectable languages

x

 7-segment display

x

  A number of actual values can be accessed via the Info button

x

  Additional functions can be programmed after opening the cover

x

  Special service level with protected access

x

  Yearly clock with automatic summer- / wintertime changeover

x

  One 7-day program per heating circuit and up to 3 switching cycles per day

can be selected on an individual basis

x

  24-hour heating program with up to 3 switching cycles

x

  7-day d.h.w. heating program with up to 3 switching cycles per day can be

selected on an individual basis

x

 Holiday program

x

  The heating programs and the d.h.w. program can be reset to their default

settings

x

  Programming lock (e.g. for child-proofing)

x

  Special mode for setting the parameters of Siemens boiler control systems

x

Market

Functions

Operating functions

Summary of Contents for QAA53.110

Page 1: ...ogram and a number of control functions Use Used in combination with a boiler controller or heating controller Room temperature control in Single or 2 family houses Smaller multifamily houses Holiday houses and villas For use in all standard heating systems such as radiator or convector heating systems Especially suited for heating plants with pump heating circuits If the boiler control systems fe...

Page 2: ...ng x x Frost warning x D h w control with release and preselection of setpoint for the boiler controller x Legionella function x Integrated yearly clock with backup minimum 12 hours x Integrated 24 hour clock with backup minimum 12 hours x Operating levels based on ergonomic and functional considerations x x Operating mode setpoint adjustment and occupancy button x x Every setting or change is dis...

Page 3: ...control only delivers a signal for controlling the heat output In the event of fault the boiler control sends message Boiler Lockout Fault to the room unit Right after the electrical connection the room unit ascertains whether the boiler controller supports the OpenTherm Plus or the OpenTherm Lite protocol Usually maximum limitation of the flow temperature is predefined by the BMU and sent to the ...

Page 4: ... interchangeable max 50 m max 2 x 5 Ω 35 mW typically Safety class Degree of protection of housing Contamination III to EN 60730 when mounted correctly IP 20 to EN 60529 environment to EN 60730 Operation Temperatures Humidity Transport Temperatures Humidity Storage Temperatures Humidity IEC 721 3 3 class 3K 5 0 50 C 85 r h IEC 721 3 2 class 2K 3 25 0 70 C 95 r h IEC 721 3 1 class 1K 3 25 70 C 95 r...

Page 5: ...as possible without being affected by direct solar radiation or other heating or cooling sources Mounting height is about 1 5 meters above the floor The unit can be fitted to most commercially available recessed conduit boxes or directly on the wall Wall mounting 2284Z33a 2284Z34a 2284Z35a Boiler control panel securing with mounting clips only QAA73 110 When using flush panel mounting the effect o...

Page 6: ...n diagram 1 2 3 4 5 6 COA COB OpenTherm terminal A interchangeable OpenTherm terminal B interchangeable 1 3 4 5 6 2 2284Z40 23 mA max QAA73 and QAA53 with Dimensions 2284M02 96 96 91 47 96 1 2 5 92 0 8 0 92 0 8 0 2284M01 96 Room unit Panel cutout ãSiemens Building Technologies Ltd Subject to alteration ...

Reviews: