» isolation:
300 V ac continuous
» relays:
» 3 alarm/control relays
» 1 form ’C’ SPDT contact per relay, rated at
5 A at 250 V ac non-inductive or 30 V dc
» dc output:
» +24 V dc
» 20 mA average to 200 mA at 1/10 duty
cycle max
Communication: »
RS-232
or
±
20 mA bipolar current loop,300,
600, 1200, 2400, 4800, 9600 or 19200 baud
Data Logs:
» variable rate on 1, 5, 15, 30 or 60 min or 24 hr
» 31 days minimum/2 years maximum
Display:
» illuminated liquid crystal 5 x 7 dot matrix
display with 2 lines of 40 characters each
Enclosure:
»Type 4X / NEMA 4X / IP65
» 209 mm W x 285 mm H x 92 mm D
(8.2" W x 11.2" H x 3.6" D)
» polycarbonate
Weight:
» 2.3 Kg (5.1 lb)
Approvals:
» CE *, FM, CSA
NRTL/C
» MCERTS Class 1 open channel flow device with environment
operation limits at 35 °C (95 °F) at 93% relative humidity
SIRA MC 050058/01
PROGRAMMER
Enclosure:
» general purpose
» 67 mm W x 100 mm H x 25 mm D
(2.6" W x 4" H x 1" D)
» ABS plastic
Operating Temperature:
» –20 to 50 °C (–5 to 122 °F)
7ML19985AB01