Installing/mounting
4.5 Installation Procedure
Milltronics MUS
24
Operating Instructions, 06/2012, 7ML19985CQ02-02
4.5.5
Position the weighmodule
Position the weigh modules so that the center of the scale idler is centered between the adjacent
approach and retreat idlers.
Ensure that the scale is centered and square to the stringers and idler, and clamping brackets
have suitable clearance.
①
Dimension 'n'
②
approach idlers
③
location of removed idler
④
retreat idlers
Note
Be sure there is sufficient clearance between the return belt, MUS, and its test weight (when
used during the calibration procedure).