Page 4
Milltronics L-300 – INSTRUCTION MANUAL
7ML19985EQ01
Installation
The L-300 flowmeter system includes:
• main body (flowguide and sensing plate housing assembly)
• sensing plate (complete with mounting hardware)
• calibration pulley
• calibration weights
• calibration weight cable
• electronic integrator (ordered separately)
Install the Milltronics L-300 flowmeter in an area that is suitable for the system
classification rating. Position the flowmeter to permit opening the housing doors for
sensing plate access.
Installing the Flowmeter
Make sure the flowmeter inlet and outlet mounting surfaces are free from excessive
vibration.
1.
Position the flowmeter into the desired location.
2.
If necessary, shim the housing base to level the flowmeter.
3.
Fasten the housing discharge to the downstream material chute.
4.
Fasten the flowguide to the material infeed chute.
5.
Install the sensing plate. Refer to the appropriate instruction manuals for levelling,
sensing plate installation and integrator interconnection instructions.
If the sensing plate has been shipped already installed, remove the shipping blocks
on the lower surface of the sensing plates.
Note:
Provide sufficient mechanical support for the flowmeter and chutework.