Issue 07/04
3 Functions
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
61
3.5.1
50/60 Hz setting
The frequency setting made in the factory can be adapted to the North American
market, without requiring any parameterization using an operator panel or PC tool
using the 50/60 Hz DIP switch (refer to Fig. 3-15).
50/60 Hz DIP switch
for frequency setting
60 Hz
50 Hz
Fig. 3-15
DIP switch to change-over between 50/60 Hz
The switch determines the value of parameter P0100 corresponding to the
following diagram (refer to Fig. 3-16). Besides P0100 = 2, after the power supply
voltage has been switched-in, the 50/60 Hz DIP switch determines the 50/60 Hz
setting (value of parameter P0100).
P0100 = 2
?
P0100 = 0
P0100 = 2
P0100 = 1
P0100 = 2
?
P0100 = 1
?
yes
yes
no
no
yes
yes
no
no
Quick
commissioning
P0010 = 1
Power
cycle
DIP2 = OFF
?
Power in kW
Frequency 50 Hz
Power in kW
Frequency 60 Hz
Power in hp
Frequency 60 Hz
Fig. 3-16
Mode of operation of the 50/60 Hz DIP switch in conjunction with P0100
Summary of Contents for MICROMASTER 420
Page 10: ...Safety Instructions Issue 07 04 MICROMASTER 420 Operating Instructions 10 6SE6400 5AA00 0BP0 ...
Page 16: ...Table of Contents Issue 07 04 MICROMASTER 420 Operating Instructions 16 6SE6400 5AA00 0BP0 ...
Page 34: ...2 Installation Issue 07 04 MICROMASTER 420 Operating Instructions 34 6SE6400 5AA00 0BP0 ...
Page 156: ...4 Troubleshooting Issue 07 04 MICROMASTER 420 Operating Instructions 156 6SE6400 5AA00 0BP0 ...
Page 166: ...6 Options Issue 07 04 MICROMASTER 420 Operating Instructions 166 6SE6400 5AA00 0BP0 ...
Page 188: ...MICROMASTER 420 Operating Instructions 188 6SE6400 5AA00 0BP0 ...