Technical data
6.4 Closed-loop control
LOGO!Power
36
Operating Instructions, 06.2014, C98130-A7560-A999-3-7629
6.4
Closed-loop control
6EP1311-1SH03
(5 V / 3 A)
6EP1311-1SH13
(5 V / 6.3 A)
6EP1321-1SH03
(12 V / 1.9 A)
6EP1322-1SH03
(12 V / 4.5 A)
6EP1351-1SH03
(15 V / 1.9 A)
Dyn. mains
compensation
(Ue rated ±15%)
0.2%
0.2%
0.2%
0.2%
0.2%
Dyn. load
compensation
(Ia: 10/90/10%), Ua ±
typ.
3%
3%
3%
4%
2.8%
Load step regulation
time 10 to 90%, typ.
2 ms
2 ms
1 ms
1 ms
1 ms
Load step regulation
time 90 to 10%, typ.
2 ms
2 ms
1 ms
1 ms
1 ms
6EP1352-1SH03
(15 V / 4 A)
6EP1331-1SH03
(24 V / 1.3 A)
6EP1332-1SH43
(24 V / 2.5 A)
6EP1332-1SH52
(24 V / 4 A)
Dyn. mains
compensation
(Ue rated ±15%)
0.2%
0.2%
0.2%
0.2%
Dyn. load
compensation
(Ia: 10/90/10%), Ua ±
typ.
3%
1%
2%
1.5%
Load step regulation
time 10 to 90%, typ.
1 ms
1 ms
1 ms
1 ms
Load step regulation
time 90 to 10%, typ.
1 ms
1 ms
1 ms
1 ms