5
Note the ambient
temperature and
ventilation
T
he clima
t
e class is s
t
a
t
ed
o
n
t
he
namepla
t
e
.
I
t
specifies
t
he r
oo
m
t
empera
t
ures sui
t
able f
o
r usin
g
t
he
appliance
.
T
he namepla
t
e is
o
n
t
he
ri
g
h
t
o
f
t
he appliance
.
Climate class
Permissible ambient
temperature
SN
+10
°
C to 32
°
C
N
+16
°
C to 32
°
C
ST
+16
°
C to 38
°
C
T
+16
°
C to 43
°
C
Ventilation
T
he air fr
o
m
t
he base panel a
t
t
he fr
o
n
t
and c
ov
er pla
t
e a
t
t
he rear hea
t
s up
.
T
he hea
t
ed air mus
t
be able
to
escape
unimpeded
.
Ot
her
w
ise,
t
he
refri
g
era
t
in
g
uni
t
has
to
wo
r
k
harder,
w
hich increases
t
he appliance’s p
ow
er
c
o
nsump
t
i
o
n
.
Y
o
u mus
t
t
heref
o
re
ne
v
er c
ov
er
o
r bl
o
c
k
t
he
v
en
t
ila
t
i
o
n
o
penin
g
s
.
In
s
talling and
connecting up the
appliance
n
T
he appliance mus
t
be ins
t
alled
and c
o
nnec
t
ed up b
y
a specialis
t
in
acc
o
rdance
w
i
t
h
t
hese assembl
y
ins
t
ruc
t
i
o
ns
.
n
O
nce
t
he appliance has been
p
o
si
t
i
o
ned,
w
ai
t
a
t
leas
t
8
h
o
urs
bef
o
re plu
gg
in
g
in
t
he mains cable
.
T
he
o
il in
t
he c
o
mpress
o
r can shif
t
to
t
he refri
g
era
t
i
o
n s
y
s
t
em durin
g
t
ransp
o
r
t.
n
Bef
o
re s
t
ar
t
in
g
t
he appliance up f
o
r
t
he firs
t
t
ime, clean i
t
s in
t
eri
o
r (see
sec
t
i
o
n Cleanin
g
t
he appliance")
.
n
T
he
w
a
t
er line mus
t
be c
o
nnec
t
ed
up bef
o
re
t
he elec
t
rical
c
o
nnec
t
i
o
ns
.
n
In addi
t
i
o
n
to
t
he s
t
a
t
u
to
r
y
na
t
i
o
nal
re
g
ula
t
i
o
ns,
t
he c
o
nnec
t
i
o
n
requiremen
t
s
o
f
t
he l
o
cal elec
t
rici
ty
and
w
a
t
er suppl
y
c
o
mpanies are
to
be
o
bser
v
ed
.
n
O
nl
y
rem
ov
e
t
he
t
ransp
o
r
t
l
o
c
k
s
o
n
t
he
t
ra
y
s and rac
k
s
o
nce
t
he
appliance has been ins
t
alled
.
n
If
t
he appliance d
oo
rs need
to
be
rem
ov
ed in
o
rder f
o
r
t
he appliance
to
fi
t
t
hr
o
u
g
h
t
he d
oo
rs
o
f
t
he
h
o
use
o
r fla
t
,
t
he d
oo
rs mus
t
be
rem
ov
ed b
y
cus
to
mer ser
v
ices
o
nl
y.
Water connection
!
Warning!
Ris
k
o
f elec
t
ric sh
o
c
k
and
o
f dama
g
e
to
pr
o
per
ty
!
Disc
o
nnec
t
t
he appliance fr
o
m
t
he
elec
t
rici
ty
mains bef
o
re carr
y
in
g
o
u
t
an
y
wo
r
k
o
n
t
he
w
a
t
er c
o
nnec
t
i
o
n
.
T
he
w
a
t
er c
o
nnec
t
i
o
n mus
t
o
nl
y
be
ins
t
alled b
y
a qualified plumber in
acc
o
rdance
w
i
t
h
t
he re
g
ula
t
i
o
ns
gov
ernin
g
t
he plumbin
g
t
rade and
t
he
l
o
cal
w
a
t
er
wo
r
k
s
.
C
o
nnec
t
t
he appliance
to
a drin
k
in
g
w
a
t
er pipeline
.
n
Minimum pressure:
1.0
bar
n
Maximum pressure:
8
.2
bar
If
t
he
w
a
t
er pressure is m
o
re
t
han
8
.2
bar, a pressure reducin
g
v
al
v
e
mus
t
be in
t
e
g
ra
t
ed
.
If
t
he
w
a
t
er
pressure is less
t
han
1.0
bar,
t
he ice
ma
k
er
w
ill n
ot
wo
r
k.
T
he
3
/
4
"
t
ap f
o
r c
o
nnec
t
in
g
t
he
encl
o
sed c
o
nnec
t
i
o
n line mus
t
be
easil
y
accessible
.
T
he c
o
nnec
t
i
o
n line has a
3
/
4
"c
o
nnec
to
r
.
T
he
t
as
t
e and smell
o
f
t
he
w
a
t
er can
be impr
ov
ed b
y
ins
t
allin
g
t
he encl
o
sed
fil
t
er car
t
rid
g
e
.
If
t
he fil
t
er car
t
rid
g
e is
used, pa
y
a
tt
en
t
i
o
n
to
t
he differen
t
c
o
nnec
t
i
o
n c
o
ndi
t
i
o
ns (see sec
t
i
o
n
"
W
a
t
er fil
t
er")
.
Connecting up the appliance
1.
C
o
nnec
t
t
he c
o
nnec
t
i
o
n line
to
t
he
appliance
.
2.
C
o
nnec
t
t
he c
o
nnec
t
i
o
n line
to
t
he
w
a
t
er
t
ap
.
3.
L
oo
p
o
r
w
ind
t
he c
o
nnec
t
i
o
n line s
o
t
ha
t
t
he appliance can be m
ov
ed
a
w
a
y
fr
o
m
t
he
w
all
.
de
en