Configuring the POCKET ISDN-TA
23
ATNxxx
all commands ATNxxx will respond OK without any
functionality behind it. V.110 baudrates can be set
with AT**BRN.
ATBxxx
All commands ATBxxx will respond OK without any
functionality behind it. The B-channel protocol
settings can be set with AT**PROT.
AT\Nxxx
All commands AT\Nxxx will respond OK without any
functionality behind it. The B-channel protocol
settings can be set with AT**PROT.
4.1.3
AT result codes
Result codes (numerical and verbose):
Code Text
Meaning
0 OK
Command
completed
1 CONNECT
<
rn
> Connection
established
(
rn
= call number of remote site)
2 RING
<
rn
>
Indicates an incoming call (SETUP
received)
3
NO CARRIER <
xx
>
No synchronization (
xx
= ISDN error cause)
4
ERROR
Illegal command or error that can not be
indicated otherwise
5
CONNECT 1200 <
rn
>
Connection, line speed 1.2 kbps (V.110)
6
NO DIALTONE <
xx
>
No access to ISDN network (
xx
= ISDN error)
7 BUSY
<
xx
>
Number engaged (
xx
= ISDN error cause)
8
NO ANSWER <
xx
>
No connection; called number can not be
reached (
xx
= ISDN error cause)
10
CONNECT 2400 <
rn
>
Connection, line speed 2.4 kbps (V.110)
11
CONNECT 4800 <
rn
>
Connection, line speed 4.8 kbps (V.110)
12
CONNECT 9600 <
rn
>
Connection, line speed 9.6 kbps (V.110)
16
CONNECT 19200 <
rn
> Connection, line speed 19.2 kbps (V.110)
19
CONNECT 64000 <
rn
> Connection, line speed 64 kbps
- RINGING
<
rn
>
Outgoing call is ringing at called site
Summary of Contents for INSYS Pocket ISDN-TA