14
Converting the gas type
If the appliance is not already set to use the type of
gas that is available, the appliance must be
converted.
Conversion to a different type of gas must be carried
out by an authorised expert and in accordance with
the applicable regulations.
The rating plate indicates the type of gas and the gas
pressure which have been pre-set in the factory.
In order to convert to a different type of gas, the
nozzles must be replaced and the low flame must be
adjusted.
Oven burner
Replacing the nozzles
Proceed as follows:
• Dismantle the shelf part of the oven.
• Loosen the screw on the front part of the oven
burner and pull it upwards slightly.
• Unscrew the nozzle and replace it with a nozzle
which is suitable for use with the new type of gas
(see "General nozzle table" section).
• To reassemble, follow the instructions in reverse
order.