System Data
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
2-16
HiPath 3000/5000 V9, Service documentation
sysdat.fm
HiPath 3000
2.1.6
Central components of the HiPath 3000 system
2.1.6.1
Central components, HiPath 3800
CBSAP
The CBSAP board performs all central control and switching functions for HiPath 3800.
The following subboards can be used depending on the application:
●
CMS clock module (optional)
●
MMC multimedia card
●
IMODN integrated modem card new (optional)
●
LIMS LAN interface module (optional)
●
Music on hold (optional):
–
MPPI
(Product of BEYERTONE GmbH)
–
MUSIC (Product of Sound Player GmbH)
LUNA2
LUNA2 is used as the central power supply in HiPath 3800. Depending on the system config-
uration up to three LUNA2 modules can be used in the basic cabinet and up to four LUNA2
modules can be used in the expansion cabinet.
LUNA2 supports power supply and battery management functions. No other components are
required if it is operated as a power supply. The following options are available for emergency
battery operation in the event of a power cut, i.e. the function UPS:
●
Connection of battery packs 4 x 12 V/7 Ah (S30122-K5950-Y200) per system cabinet.
●
Connection of the Power Box PB3000 with 4 batteries 12 V/7 Ah (4 x V39113-W5123-
E891) per system cabinet.