Modules
3-98
Service Manual
Batteries
PSU Connector assignments
Table 3-34
PSU Connector assignments for HiPath1150/1190/1190R
3.8
Batteries
The HiPath1150/1190/1190R systems can be powered with batteries if the AC line is down,
thus guaranteeing a continuous electrical supply to telephony services. Battery duty cycle
varies according to the capacity of the battery installed
Systems and battery set (2x12v) are joined by a connection cable (see “Battery interconnect
cables (BBU)” on page 3-122)
Note: The power supply used in the systems must have a battery connection socket (BBU) (see
“Power Supply Unit (PSU)” on page 3-93).
Warning
If the power supply is not supplying the output voltages shown in Table 3-34, open
it and check the condition of the fuses.
Contact
Function Contact
Function
1
+5.1 V
DC
2
+5.1 V
DC
3
+5.1 V
DC
4
+5.1 V
DC
5
+5.1 V
DC
6
+5.1 V
DC
7
GND
8
GND
9
GND
10
GND
11
GND
12
GND
13
26.4 V
DC
14
26.4 V
DC
15
26.4 V
DC
16
26.4 V
DC
17
26.4 V
DC
18
26.4 V
DC
19
GND
20
GND
21
GND
22
GND
23
GND
24
GND
25
50 V
AC
+ 97 V
DC
42 V
AC
+ 85.8 V
DC
(RSA)
26
50 V
AC
+ 97 V
DC
42 V
AC
+ 85.8 V
DC
(RSA)
!
Summary of Contents for HiPath 1100
Page 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Page 14: ...Figures 14 Service Manual ...
Page 124: ...Modules 3 124 Service Manual Interconnect cables ...
Page 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Page 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Page 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Page 384: ...Abbreviations 9 384 Service Manual ...
Page 388: ...388 Service Manual ...