Hicom 102-Technical Specifications/ Installation and Start-up Instructions 

5.        Important Notes 
5.1

 

Placing 

in 

Service 

Modification of customer data can only be done at the express 
wish of the customer and only at a fee. 

5.2

 

Exchange Lines 

-

 

The exchange feeding voltage must be at least 48 V, otherwise 
serious functional disturbances may result. 

-

 

The presence of an exchange line is automatically detected by 
the Hicom 102 after the AC power is connected. For this reason 
after connecting an exchange line, the system must be briefly 
switched off. 

5

.

3

 

Outward Restriction of Trunk Access 

B y  deletion of a user in the line assignment, he can be given 
outward restriction of trunk access, i.e. he can set up no outside 
calls. 

5.4

 

Printer Connection 

Attention: 

The printer connection, for which provision is made, is nor being 
supplied at present. 

5.4.1

 

Interface Data

 

-

 

Interface via  RS 232 C (V.24) 

-

 

Port speed 4800 bit/s 

-

 

interface allocation  

 
 
 
 
 
 

5.4.2

 

Printer functions 

-

 

Automatic printout of the following data at end of call (only 
for outgoing calls) 

 

calling party's call number 

 

external call number 

 

call duration 

-

 

Printout of the current system programming 

 

printout follows selection of code 19998 on the master 
station 

5.5

 

Suppression of Gaps in the Feeding Current 

In certain cases due to interruptions in the feeding current after 
exchange seizure, the terminal functions may be affected, e.g. 
discontinuation of dialing after exchange seizure or obtaining of 
wrong numbers. 

In these cases the feeding current gaps can be bridged for 
individual users or for all users (for procedures see 4.4 
"Interpretation of exchange tone") 

In this case, however, exchange seizure is generally performed 
with 

delay. 

5.6

 

Connection of Second Ringers 

If additional second ringers or telephones are connected (e.g. via 
AWADO) there may be problems with the ringing signal voltage. 
It must be ensured, that not more than six ringers sound 
simultaneously. 
(Usual ringer impedance: approx. 7k ohms) 

 
 
 
 

 

 

 

 
Gnd

 

= signal ground 

RTS

 

= request to send 

RXD

 

receive data 

TXD

 

= transmitted data 

 

 

A30950-M78-X-3-7628 

Summary of Contents for Hicom 102

Page 1: ...feed voltage at least 48 V No satellite PABX traffic is possible 1 6 Power Failure Transfer ALUM Trunk transfer occurs upon failure of the power network voltage First trunk to subscriber 1 master station Second trunk to subscriber 2 1 7 Entrance Telephone call number 7 Range Maximum line resistance DC free no feed Activation contact for entrance telephone Neutral NO contact max 0 3 A 24 V Contact ...

Page 2: ...telephone Answer 7 Answer and actuate door opener 7 77 Call hold with DP 0 with DTMF flash key Call forwarding activate own user No destination user No deactivate 2 x own user No Do not disturb except master stn activate own user No 0 deactivate 2 x own user No 4 3 Codes for the Master Station Night service feature activate 10 deactivate 11 4 4 Programmable Functions for the Master Station Activat...

Page 3: ...tion 5 4 2 Printer functions Automatic printout of the following data at end of call only for outgoing calls calling party s call number external call number call duration Printout of the current system programming printout follows selection of code 19998 on the master station 5 5 Suppression of Gaps in the Feeding Current In certain cases due to interruptions in the feeding current after exchange...

Page 4: ...unctional range of the subscriber lines 2 X 60 ohms With a copper wire cable with a conductor diameter of 0 4 mm this corresponds to a max line length of 430m Note The subscriber line must not be laid across extraneous land A line to adjacent premises is permissible Line network To the door opener 1 2 7 8 3 4 5 For the door opener function plug the door opener relay TO V2304O AG02 B2Q1 into the IC...

Reviews: