HART add-on module
10. Device-Specific Commands
Command Number and
Data in Command
Data in reply
Function
171
Read totalizer
Byte 0
Totalizer no.
Byte 0
Unit code
0 = Totalizer 1
Byte 1-4
Totalizer value
1 = Totalizer 2
Byte 5
Totalizer no.
172
Read status data
Byte 0
log type
Byte 0
As in command
0 = Error Pending
Byte 1-18
9 logs consisting
1 = Status Log
of two bytes,
Can Error
Number
173
Read status timestamp
Byte 0
log type
Byte 0-2
As in command
Byte 1
Canapp_ID
Byte 3-12
days, hours and
Byte 2
ErrorNumber
minutes
180
Write Currentoutput1
Byte 0
0 = Off
As command
(MASS 6000 only)
1 = Massflow
2 = Fraction A
3 = Fraction B
4 = Volumeflow
5 = Sensor temperature
6 = Density
7 = Pct. Fraction A
181
Read Currentoutput1
None
Byte 0
0 = Off
(MASS 6000 only)
1 = Massflow
2 = Fraction A
3 = Fraction B
4 = Volumeflow
5 = Sensor
temperature
6 = Density
7 = Pct. Fraction A
182
Write Digitaloutput1
Byte 0
0 = Off
As command
1 = Pulse
2 = Frequency
3 = Error level
4 = Error number
5 = Direction/Limit
6 = Batch
183
Read Digitaloutput
None
Byte 0
0 = Off
1 = Pulse
2 = Frequency
3 = Error level
4 = Error number
5 = Direction/Limit
6 = Batch
184
Write Relayoutput1
MAG 5000 C/6000
As command
Byte 0
0 = Off
3 = Error level
4 = Error number
5 = Direction/Limit
6 = Batch
7 = Cleaning
MASS 6000
Byte 0
0 = Off
3 = Error level
4 = Error number
5 = Direction/Limit