4. 

Install the hotplate in the cut-out (See diagram B). 

 

5. 

The gas connection to the regulator is 1/2” BSP.  The regulator should be held by a 
spanner on the flats provided when making the joins.  Turn the gas on and check for 
leaks using a soap solution and brush around all joints and connections.   

 

Pressure test point:  

-

 

This is provided in the gas regulator.   

-

 

Remove the screw, connect the hose from the pressure gauge.   

-

 

Turn on the gas to the large burner and manually light the burner.   

-

 

The pressure is shown on the data plate. 

-

 

To increase the pressure, loosen locking nut and turn clockwise.   

-

 

Disconnect gauge and replace test point screw. 

 

6. 

Test the appliance:   

-

 

Depress the control knob and turn to full flame setting.   

-

 

The burner will ignite.  Adjust control knob to desired setting.   Normally, no 
adjustment should be necessary.   

-

 

If any problems occur, refer to the servicing instructions or fault isolation chart. 

 

7. 

Instruct the user to keep the users instructions manual. 

  If any of the above procedures do not produce satisfactory results, the    
  agent’s service department should be consulted for more specialized assistance. 

 

8. 

The cooktop is fitted with the flame failure device that cuts off the gas supply when 
burner flame extinguishes suddenly or abnormally in order to avoid the gas leakage. 

 

9. 

Room Ventilation - This cooktop must be installed in a room that has permanent 
ventilation to effect the correct operation of the appliances and also to provide 
adequate ventilation.  This airflow must exceed 20m³ via permanent vented openings 
in the walls of the room and these must have a section of 100cm² minimum.  They 
must be constructed in a manner so as to avoid any possible blockages.  The airflow 
can also be drawn indirectly from an adjacent room provided it complies with any 
local regulations to vent any fumes outdoors.  

 

WARNING: 

-

 

Do not spray aerosols in the vicinity of this hotplate while it is in operation. 

 

-

 

Some propellant gases can break down when heated and produce corrosive vapours 
which will attack some materials. 

 

-

 

Articles which are made of flammable materials should not be stored in drawers or 
cupboards immediately below this hotplate. 

 

-

 

The silicone rubber gasket should not be removed under any circumstances.  In the 
event that any protective rubber gasket is dropped off or damaged, the consumer 
should cease forthwith the use of the unit until it is duly rectified. 

 

-

 

Do not store articles within 50mm of the bottom of the hotplate casing. 

 

-

 

Do not touch spark igniter while lighting the burner.  

 

-

 

When the appliance is installed in a marine craft or in caravans, it shall not be used as 
a space heater. 

Summary of Contents for ER70762HK

Page 1: ...Gas Built in Hob 2 BURNER GAS HOB ER70762HK Town gas model 3 BURNER GAS HOB ER70962HK Town gas model ER70926HK ER70922HK LPG models Installation and operating instructions 04 2011 ...

Page 2: ...the conservation of the environment by depositing the packaging in the nearest recycling container Used oil should not be poured down the sink as this causes serious damage to the environment Pour it into a sealable container and take it to a recycling point or simply put in your rubbish bin It will then finish up in a controlled landfill site which though it is not the perfect solution it does pr...

Page 3: ... Installation Instructions 4 5 Servicing Instructions 6 Minor Adjustments 6 Fault Isolation Chart 6 Operating Instructions 7 Hints On Use of The Hotplate 8 Recognizing Abnormal Operation 9 Specification Tables 10 ...

Page 4: ...the position shown in Diagram A 2 Cut the opening in the bench top to the dimensions shown in diagram B 3 Remove the hotplate from the carton Models ER70762HK Models ER70962HK ER70926HK ER70922HK If clearance between side and rear walls and periphery of the burner is less than 150mm the walls must be protected with a non combustible material The protection must extend a minimum distance of 450mm a...

Page 5: ...rner flame extinguishes suddenly or abnormally in order to avoid the gas leakage 9 Room Ventilation This cooktop must be installed in a room that has permanent ventilation to effect the correct operation of the appliances and also to provide adequate ventilation This airflow must exceed 20m via permanent vented openings in the walls of the room and these must have a section of 100cm minimum They m...

Page 6: ... Remove screw from the clamp holding the electrode and thermocouple and note the adjustment setting height of each Replace electrode and then fit clamp and screw FAULT ISOLATION CHART FAULT CAUSES REMEDY Burner will not light 1 Air in gas line 2 Blockage in line 3 Ignition not sparking 4 Flame failure device faulty 5 Check the battery applicable to DC version 1 Purge gas line 2 Trace back and clea...

Page 7: ...me adjustment is achieved by rotating the control knob further in an anti clockwise fashion towards the pre set simmer position BATTERY REPLACEMENT applicable to battery ignition model 1 Open the battery holder cover flap 2 Remove old battery 3 Replace with new 1 5 Volt D size battery noting correct polarity 4 Close cover flap CLEANING Allow the Hobcooker to cool before attempting to dismantle or ...

Page 8: ...the hotplate Do not use large pots or heavy weights which can bend the pan support or deflect the flame onto the hotplate Locate pan centrally over burner so that it is stable and does not overhang the appliance Use only wok support supplied or recommended by the manufacturer of the appliance Additional Installation Instruction Connection of LPG or TG rubber tube It must be used approved rubber tu...

Page 9: ...er head are not obstructed In the event that you are not satisfied with the hotplate the distributor in your State should be consulted IMPORTANT Under the Gas Safety Registration of Gas Installers and Gas Contractors Regulations only registered gas installers registered to the appropriate class employed by registered gas contractors can personally carry out gas installation work Gas Installation W...

Page 10: ...70926HK ER70962HK Ignition DC 1 5V Battery DC 1 5V Battery DC 1 5V Battery Top plate material 8mm toughened 8mm toughened 8mm toughened Glass colour White Black Black Glass shape Curved Sides Curved Sides Curved Sides Burner Configuration 3 3 3 Gas Type LPG LPG LPG Heat input for burner kW Mj hr Left Centre Right 4 4 15 84 1 3 4 68 4 4 15 84 4 2 15 00 1 1 3 8 4 2 15 00 4 4 15 84 1 3 4 68 4 4 15 84...

Page 11: ...11 氣體嵌入式平面爐 雙頭氣體爐 ER70762HK 煤氣 三頭氣體爐 ER70962HK 煤氣 ER70926HK ER70922HK 石油氣 ...

Page 12: ...12 安裝及操作說明書 06 2010 目錄 安裝說明 14 15 維修說明 16 細火調節 16 故障檢索表 16 操作說明 17 爐具使用要訣 18 識別異常操作 19 產品資料表 20 ...

Page 13: ...13 前言 必須按照製造商的說明 相關的氣體安裝規定 認可的燃氣爐具安裝指引及 其它法例和守則 初次使用之前應詳細閱讀本說明 並妥善保管 以便充分利用嵌入式平面爐的 功能 注意 根據香港法例第 51 章氣體安全規定 任何氣體配件 包括接駁軟喉 的安裝 更換必 須由香港政府註冊氣體工程承辦商僱用的註冊氣體裝置技工負責 否則即屬違法 ...

Page 14: ...首先檢查資料標識 查看本爐具是否適合使用現時的氣體供應 1 安裝本爐具前 檢查確保安裝位置要遠離易燃材料 必要時 按法例規定要求 對爐具周圍提供保護措施 將氣體供氣連接於圖 A 所示的進氣口 2 將檯面切成圖 B 所示的尺寸 3 從紙盒中取出爐具 Models ER70762HK Models ER70962HK ER70926HK ER70922HK 如果側面及後面的牆壁離爐具外圍不足 150 毫米 必須用非易燃材料保護牆壁 Gas inlet Gas inlet ...

Page 15: ...回測試點螺絲 6 本爐具的測試 按下控制旋鈕 旋轉至最大火燄 爐頭將點火 將控制旋鈕調整至所需的設定 一般無需調整 如果出現問題 請參閱維修說明或故障檢索表 7 確保用戶留有使用說明書 如果上述任何程序結果不滿意 應向代理商之維修部查詢 尋求專業協助 8 本爐具配有火焰熄滅關氣裝置 爐頭火焰突然熄滅或者燃燒不正常時 該安全 裝置自動切斷燃氣供應 避免發生漏氣事故 9 室內通風 爐具必須安裝於設有永久通風裝置的室內 從而提供適當的流通空氣 位於室 內的永久通風口不能少於 100 平方厘米 及流通空氣不能少於 20 立方米 通風 口必須沒有任何阻塞 在乎合當地有關煙氣排出室外的規例下 流通空氣亦可 間接從相連房間進入 警告 爐具在使用的過程中 請勿在附近噴氣溶膠 在高溫時 有些壓縮燃氣會發生化學變化 產生一些侵蝕某些材料的腐蝕性氣 化體 本爐具下的抽屜或廚櫃中 不得存放易燃材料製成的物件 在任...

Page 16: ...爐頭和爐頭組件入口 取下玻璃爐面和控制旋鈕 拆下氣體塞 鬆動鎖緊螺母 在氣塞與爐頭之間 取下螺絲 現在可以從歧管 上取下氣塞 如果需要接觸筒管 取下將軸固定於爐具的兩個螺 絲 潤滑機械裝置時 請使用認可的油脂 更換電極方法 進行本程序之前 請先將爐具與電源隔離 1 取下玻璃爐面及控制旋鈕 2 將電極引線從火花控制盒插座上拔出 3 拆掉圍繞瓷質電極體的彈簧圈 4 從支座上拆出電極 5 組裝 電極組裝步驟與上述拆除步驟相反 故障檢索表 故障 原因 解決方法 爐頭點不著火 1 氣體管道中有空氣 2 管道堵塞 3 點火無火花 4 防漏熄火裝置有故障 5 檢查電池 適用於配有電池型號 1 吹掃管道 2 查找和清理 3 檢查導線和電極 4 更換熱電偶並測試 5 更換電池 爐頭點燃至噴嘴 1 爐頭混合管毛絨過多 2 氣體壓力過大 1 取下爐頭進行清潔 2 檢查氣體調節器壓力 必要時予 以調整 爐頭點火時...

Page 17: ...放置大鑊 點火 此爐具的每個爐頭均配有電子點火設備 通過按壓單個控制旋鈕 按逆時針方向轉 周進行操作 控制器 此爐具的每個爐頭都有獨立控制旋鈕 位於玻璃面的前方 指示符號可以顯示哪個 旋鈕控制哪個爐頭 在每個爐頭控制旋鈕旁的玻璃面上有大小火燄圖 表示 FULL ON 大火 和預設的 文火 位置 爐頭的操作 1 按下需要的控制旋鈕 按逆時針方向轉至 FULL ON 大火 位置 2 爐頭點火後 將控制旋鈕調整至需要的設定 按逆時針方向再旋轉旋鈕至預設 的 文火 位置 即可以調整火燄大小 更換電池 適用於電池點火型號 1 打開電池盒蓋 2 取出舊電池 3 放入新 1 5 伏特 D 型電池 4 關上電池盒蓋 清潔 等待爐具冷卻後再自行拆卸或清潔 用一塊布以暖肥皂水清潔玻璃面 則效果 最佳 盡量避免使用洗潔粉及洗潔劑 但必要時請用柔性洗潔材料 為了去除 頑固的油脂 可以使用塗上肥皂水的鋼絨刷 高濃度...

Page 18: ...過熱 大口徑器皿 口徑超過 200 毫米 不得突出爐面的外圍 否則可能使 附近櫃面過熱或造成損壞 在鑊和爐架之間請勿放置任何東西 如火燄撲滅器 石棉毯 等 否則 會對本爐具造成嚴重損壞 請勿取下爐架及用鑊架圈在爐頭的周圍 否則 會使火燄聚 中 將熱力反射到爐面上 請勿使用大壺或重物 爐架會變彎或將火燄反射到爐面上 將鑊放在爐頭的中央 放穩 勿使爐具過偏 請僅使用供應的本爐具製造商推介的鑊架 安裝說明 石油氣或煤氣膠喉之接駁 必須使用合格印有機電工程署批准標記 例如 機電工程署批准 EMSD Approval GTXXXX 字樣 之膠喉及供應管道式石油氣或煤氣使用的溢流掣或 瓶裝石油氣使用調壓器進行接駁 煤氣不銹鋼軟喉接駁 必須使用合格印有機電工程署批准標記 例如 機電工程署批准 EMSD Approval GTXXXX 之不銹鋼軟喉及溢流掣或氣掣進行接駁 ...

Page 19: ...品 可能造成個人身 體傷害 識別異常操作 出現故障 致電給維修代理之前 請檢查下列各項 不能點火 檢查是否有東西堵塞電極金屬尖 無氣體 檢查主氣體表處的氣體開關是否打開 爐火燃燒不勻 檢查爐頭是否放置平穩 爐頭中的槽口未被堵塞 如果您對爐具效果不滿意 請到本地的經銷商處諮詢 注意 根據香港法例第 51 章氣體安全規定 任何氣體配件 包括接駁軟喉 的安裝 更 換必須由香港政府註冊氣體工程承辦商僱用的註冊氣體裝置技工負責 否則即屬違 法 您的爐具是由強化玻璃造成 在正常使用下 非常堅固耐用 在第一次使用爐具之 前 請閱讀 安裝及操作說明書 內之操作建議 不要使用錫紙碟 錫紙碟可引致爐火不正常 安全距離尺寸圖 ...

Page 20: ...nnection Screw 1 2 inch BSP Screw 1 2 inch BSP Model number Items Unit ER70922HK ER70926HK ER70962HK Ignition DC 1 5V Battery DC 1 5V Battery DC 1 5V Battery Top plate material 8mm toughened 8mm toughened 8mm toughened Glass colour White Black Black Glass shape Curved Sides Curved Sides Curved Sides Burner Configuration 3 3 3 Gas Type LPG LPG LPG Heat input for burner kW Mj hr Left Centre Right 4 ...

Reviews: