Fire Safety & Security Products
Siemens Building Technologies
¼” High Speed Dome Camera CCDA1435-DNX
Quick Installation Guide
5
COM
Alarm1
Alarm2
Alarm3
N.O(Normal Open)
Alarm4
GND
N.C(Normal Close)
Data
+
Data-
7
6
9
8
10
D
E
5
11
134
Unit:mm
1
4
3
2
220
164
C
A
B
1
Dome base
5
Mounting brackets
9
BNC connector
2
Hook
6
Switch for termination
10
Notch for installation
3
Support wire
7
Terminal for control & Alarm IN/OUT
11
Installation label
4
Dome drive
8
Terminal for power
Control unit CKA482
0
Dome 1
Dome 10
. . .
RS485
TTY
TTY
SIMATRIX 648
Control unit CKA4820
Control unit CKA4820
DomeConverter CAC0103
Dome 1
Dome 10
. . .
RS485
RS485
Interface multiplier
CAD0485-AA
WARNING
1.
To reduce the risk of fire or electrical shock, do not expose this product to
rain or moisture.
2.
This installation should be made by a qualified service person and should
conform to all local codes.
3.
Connect the equipment to 24 VAC UL Listed Class 2 Power Supply.
CAUTION
1.
To reduce the risk of electric shock, do not remove cover (or back). No user-
serviceable parts inside.
2.
Servicing should only be carried out by qualified service personnel.
3.
Ensure that the safety wire (located in the dome base) is engaged.
4.
Align notch with "OPEN" arrow and turn dome until notch meets arrow in
"LOCKED" position.
5.
Check assembly by pulling on dome. Assembly should
not come apart.
6.
Only use the supplied EMI core for the power supply.