background image

 

© Siemens Building Technologies AG

Document No.:

 

A24205-A336-B323, Issue: 04.2006 

Data subject to change without notice

 

Package contents 

z

 

Dome base 

z

 

Dome drive 

z

 

3 mounting screws 

z

 

Installation and operating instructions 

z

 

EMI-Core 

 

Installation 

1. 

Setup the DIP switch on Dome base 
and Dome drive to select baud rate, 
address and protocol (see chap. 3.3 
in installation manual for details). 

2. 

Refer to Fig. A to install the dome 
base and dome drive. Connect the 
support wire (3) to the hook (2) of 
the dome base (1) carefully to 
prevent the dome from dropping. 

3. 

To lock the dome drive (4) to the 
dome base, line up the notch (10) to 
the right arrow on the label (11) then 
turn dome drive to right with both 
hands (see figure C) till the notch 
lines up to left arrow. 

4. 

Various accessories are available 
for indoor or outdoor installation 
(see Section 9 in the instruction 
manual for installation details). 

5. 

Connect video cable: connect BNC 
connector VIDEO OUT (9) to the 
monitor with a coax cable. 

6. 

Connect RS485 interface: Connect 
RS485 wire from control device to 
the Data+/Data- terminal (7). 

7. 

 Ensure that only last dome in 
RS485-chain is terminated by 
setting termination switch (6) to 
position on. 

8. 

Connect control signal: 4 alarm IN 
and 2 alarm OUT terminals are 
available (7) 

9. 

Connect power supply (8): Only 24 
V AC ±10% power can be supplied 
for this product, voltage over this 
range will damage the product. 

 

Connections 

One or multiple speed domes can be 
controlled via a control panel (see Fig. 
D) or a matrix connection (see Fig. E). 
 

Start up procedure 

When powered up, the Speed dome will 
perform a brief homing routine during 
which it checks its function and will then 
go its start position. The camera 
information including model number, 
software version, protocol, address 
setting and communication baud rate 
are displayed on the screen.  

 
 

Operation  

After power-up, you can use the control 
panel to control the pan/tilt and zoom 
functions. Some speed dome functions 
are operated via preset commands. 
Please refer to the table below. 
 

Camera OSD Setup  

Press 65 POS to enter the OSD menu. 
Most camera settings including pan/tilt 
settings, preset settings and others are 
configured here. Please refer to the 
installation manual for details. 
 
 
 
 
 

Maintenance 

 

All electrical and electronic 
products should be disposed 
of separately from the 
municipal waste stream via 
designated collection 
facilities appointed by the 
government or the local 
authorities. 

 

 

Technical Data 

Part no. 

2GF1193-8AD

Description 

¼-inch CCD Day Night High Speed Dome 

Operating temperature 

0 – 50 °C / (32 – 122 °F) 

Storage temperature 

-20 –+ 60 °C / (-4 –+140 °F) 

Weight 1.75 

kg

Power supply 

24 V AC ±10% / 50 Hz 

Power consumption 20 

VA

Interface RS485
Protocol* 

Siemens, Pelco-D/-P, VCL, Kalatel, Ernitec, Sensomatic, Molynx-D 

Data rate 

2400, 4800, 9600, 19200 (DIP SW selectable) 

* 3

rd

 party protocols may vary without further notice. 

English  

 

 

For more detailed information please refer to the Instruction Manual for ¼" Speed Dome Cameras. 

Deutsch  

 

 

Nähere Informationen hierzu finden Sie im Installationshandbuch für ¼" Speed Dome Kameras. 

Français  

 

 

Veuillez consultez le guide d'opération des cameras ¼" Speed Dome pour d’information plus détaillée.

Nederlands  

 

 

Uitgebreide Informatie find u in het instruktie handboek voor ¼ Speed Dome Kameras. 

Italiano  

 

 

Per maggiori dettagli si rimanda al manuale specifico di istruzione della telecamera Speed Dome ¼". 

Polski  

 

 

Wi

ę

cej informacji zawiera instrukcja obs

ł

ugi zintegrowanej kamery szybkoobrotowej ¼”. 

Svenska  

 

 

För ytterligare information hänvisas till installationsmanualen för ¼" Speed Dome Cameras. 

Español  

 

 

Por favor, para una información más detallada, consulte con el manual de instrucciones de los domos 
de alta velocidad de ¼”.  

Č

esky  

 

 

Pro podrobn

ě

jší informace se prosím podívejte do návodu pro obsluhu ¼" Speed Dome kamery. 

Portugues 

 

 

Para mais informações, consulte o Manual do utilizador das Câmaras ¼" Speed Dome. 

 

 

<CAMERA  SETUP>

<PAN/TILT  SETUP> 

<PRESET  TITLES> 

<OTHERS>

 

EXIT

 

SIEMENS 
(Model) 
VERSION*** 
PROTOCOL*** 
ADDRESS** 
COMM***

 

Reviews: