Connection
23
Siemens AG
03.2011
1
RS-485(+) Green
2
RS-485(-) Blue
8.1.3
Twisted-pair video output
1
TP-A(+)
Yellow
TP output A
2
TP-B (-)
Green/White
TP output B
ON
1 2 3 4
Switch
description
S1 S2 S3 S4 Note
Off
Off
2.0
Vpp
On
Off
2.6
Vpp
Output voltage without accentuation
On
On
3.2
Vpp
Off Off
0
dB
Off On
6
dB
On Off
6
dB
Frequency-dependent accentuation
at 5 MHz
On On
12
dB
Condition
on
delivery
On Off Off Off
8.1.4
Alarm output
The alarm output (motion detection result or face detection result or external signal
fed in) is active high.
1
Alarm output
Violet
2
GND Black