Information and Communication Products
Communication Devices
V1.2
Page
15
of 34
ICP CD ST
D. Schnoor
8/99
5.4
Repair Documentation
5.4.1 Description of procedure:
5.4.1.1 Diagnosis
The 18µH coil is used in the step up converter which is generating a
5.4 V supply voltage for the power amplifier out of the 2.8V battery
voltage.
If the coil is mechanically damaged (broken) it produces heavy
interference with the acoustical elements of the C25 resulting in a loud
humming noise in the earpiece.
A broken coil can easily be diagnosed by trying to move it with two
fingers. If it moves, the core is broken and the coil has to be
replaced.
5.4.1.2 Repair by component change
Use hot air to remove defective coil.
Avoid excessive heat!
Watch surrounding components!!
Resolder new coil afterwards
5.4.1.3 Repair by SW-Booting
Not possible!
5.4.1.4 Test
Retest handset after repair by checking the audio quality with the echo
loop of the testprogram.
Summary of Contents for C25
Page 67: ......