Product upgradation is a continuous process. Hence, data in 

this leaflet is subject to change without prior notice. For the 
latest information, please contact our sales Offices.

Order No.  

4P-0008-0117366 301 

Customer Care Toll free no. 1800 220 987 / 1800 209 0987  Email: [email protected]

PLASTICS : Segregate as per material type for recycling 
through authorised dealer.
Because of the long lifetime of Siemens products the 
disposal guidelines may be replaced by other national 
regulations when taking the product out of service.  
The local customer care service is available at any time  
to answer disposal-related questions

Siemens Products are environment friendly, which 
predominantly consist of recyclable materials.
For disposal we recommend disassembling and  
separation into following materials: 
METALS : Segregate into Ferrous & Non Ferrous types for 
recycling through authorised dealer.

Disposal 

Dimensional Drawings (all dimensions in mm) 

3TE05..-2AR0

Table 2 : Hardware Information

kW

Incoming Terminals

Outgoing Terminals

Tightening Torque

75

M6

M6

8-10 Nm

90

M6

M6

8-10 Nm

110

M6

M6

8-10 Nm

132

M8

M8

12-16 Nm

Spares List

Spares:
Type of Spares

MLFB/Catalogue Number-Make

Make

ON/OFF Actuator

3SB5201-7EC01

Siemens

Electronic Timer

3RP15 76 -1NM20 8K

Siemens

Relay

As per Table 1

Siemens

Lock with key

MS 748-3 with Cam 12mm

Arihant Panel fittings

Lock without key

MS 714-2 with Cam 12mm

Arihant Panel fittings

Figure 8: External and Mounting Dimensions

Front view

Summary of Contents for Automatic Star-Delta 3TE05 2AR0 Series

Page 1: ...upon location of incoming and outgoing cables remove corresponding rubber Grommets Ensure dust proofing by using proper cable glands 5 Select Correct Size of Cables as specified in selection Table 1 Remove required length of insulation and using the hardware specified refer table 2 at the connection terminals fix the incoming and outgoing cables Tighten the screws firmly 6 Check that line and moto...

Page 2: ...erage tripping time at different multiples of set current Caution 1 Switch OFF the Starter and disconnect the main supply by switching OFF the main switch before doing any maintenance 2 Under No Circumstances should the Relay be set higher than phase current i e 0 58 times the rated current on the motor nameplate 3 If the Relay trip even when set at the rated Motor current the suitability of the s...

Page 3: ... it will be automatically reset in maximum 4 minutes The Motor can be restarted only after the relay is reset H Hand Reset A Auto Reset Blue Reset Knob Figure 6 Relay Front View Q1 Line Contactor Q2 Star Contactor Q3 Delta Contactor S1 ON Push Button I S0 OFF Push Button O S4 Reset Button of relay K1 Bimetal Relay Q4 Star Delta Timer Maintenance 1 Keep the interior dust free 2 Check the tightening...

Page 4: ...ns Siemens Products are environment friendly which predominantly consist of recyclable materials For disposal we recommend disassembling and separation into following materials METALS Segregate into Ferrous Non Ferrous types for recycling through authorised dealer Disposal Dimensional Drawings all dimensions in mm 3TE05 2AR0 Table 2 Hardware Information kW Incoming Terminals Outgoing Terminals Tig...

Reviews: