background image

AR4

0

S-MF

AR1

0

S-MF

AR10S-MF

  

AR40S-MF

 

Installation

 

and

 

Mounting

Version

 

9.0

Siemens Switzerland Ltd

Summary of Contents for AR10S-MF

Page 1: ...AR40S MF AR10S MF AR10S MF AR40S MF Installation and Mounting Version 9 0 Siemens Switzerland Ltd ...

Page 2: ... the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100010 9 ...

Page 3: ...connecting 9 5 1 Surface mounted reader 10 5 2 Surface mounted reader with cables fed from outside 11 5 3 Back box mounted reader 13 5 4 Back box mounted reader with adapter plate 14 5 5 Connecting the cables 15 5 6 Disassembling the reader 17 6 Default settings 18 7 Connecting card reader to SiPass integrated 19 7 1 Setting the card reader address 19 8 Disposal 21 ...

Page 4: ...ation from neither the reader nor the system they are connected to can be extracted They are made of hardwearing materials and will endure most weather conditions The readers are easy to mount and connect and can be mounted on a flat surface or partly inside a back box They can be cleaned with most kinds of domestic detergents Both readers have a multicolour light frame The AR40S MF has a keypad a...

Page 5: ... green 1 x Buzzer Multicolor light frame Keypad No Yes Display No Yes graphic monochrome OLED Operating temperature 40 C to 55 C 40 C to 55 C IP rating IP55 IP55 IK class 08 08 Housing Zinc casted metal bezel with polycarbonate plastic front Zinc casted metal bezel with polycarbonate plastic front Color Black matt chrome Black matt chrome Dimensions W x H x D Surface mounted 85 x 114 x 22 Back box...

Page 6: ...in compliance with the essential requirements and other relevant provisions of Radio Equipment Directive 2014 53 EU The EC Declaration of Conformity is available from your Siemens sales office or Siemens Switzerland Ltd Gubelstrasse 22 6300 Zug Switzerland 3 2 FCC statements 6 Siemens Switzerland Ltd 2017 07 14 Model No AR10S MF AR40S MF FCC ID 2AHDLNGCR 2AHDLNGCR This device complies with part 15...

Page 7: ...ader components 4 Reader components 1 Hinge 6 Screw for removal from wall tamper protection 2 Base 7 Front 3 Cord gasket 8 Back box plate 4 Knock outs x 4 5 Tamper base 7 Siemens Switzerland Ltd 2017 07 14 ...

Page 8: ...4 Reader components 1 Screws for back box plate 2 Connector 3 Opening tool please note that this is a symbolic depiction of the opening tool 8 Siemens Switzerland Ltd 2017 07 14 ...

Page 9: ...identify the parts which are needed for the appropriate alternative Please refer to respective page for l Surface mounted reader on the next page the reader is mounted on the base which first is fastened on a wall l Surface mounted reader with cables fed from outside on page 11 the reader is mounted on the base and the cables are connected via one of the knock outs l Back box mounted reader on pag...

Page 10: ...es will be pushed through this hole 2 Attach the base to the wall with three screws one in the middle at the top of the base and two in the corners at the bottom of the base 3 In case that the removal from wall tamper protection is required fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 4 Continue to follow the instructions...

Page 11: ...ch of the knock outs the cables should be fed through 3 Insert the flat head screw driver in the pocket of the knock out 4 Hammer the screw driver handle This will create enough pressure to crack the exact area of the base which will release the knock out 5 Tilt the knock out with the screwdriver 6 Pull the knock out away from the base 11 Siemens Switzerland Ltd 2017 07 14 ...

Page 12: ...uired fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 9 Feed the cables through the opening and reinsert the cord gasket Proceed to the instructions for Connecting the cables on page 15 It is recommended to seal the gap which the knock out creates Please note that a reader with a removed knock out is not IP 55 12 Siemens Swi...

Page 13: ...Attach the extra screws at the lower part of the back box plate in order to prevent rotation Use only the screws included in the packet for the lower part of the base since those ensure that the reader front will fit perfectly to be securely fitted over the back box 3 Continue to follow the instructions for Connecting the cables on page 15 13 Siemens Switzerland Ltd 2017 07 14 ...

Page 14: ... indicators on the connector and the base A B 2 Snap the connector in place 3 Push the cables back 4 On the backside of the front there is an EOL jumper used for RS485 bus ter mination see illustration By default the reader has the termination ON and acts as the last reader on the bus But if it is an intermediate reader on the bus the jumper must be removed or placed in OFF position 5 Place the fr...

Page 15: ...5 Mounting and connecting 6 Fold the front down until the snap lock confirms a secure attachment 15 Siemens Switzerland Ltd 2017 07 14 ...

Page 16: ... Carefully insert the opening tool in the slot between the base and the front 2 Push gently and lift the front of the base To remove the connector 1 Insert the opening tool as indicated on the picture 2 Push down gently and tilt the connector away from the base 16 Siemens Switzerland Ltd 2017 07 14 ...

Page 17: ...d activation are possible Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 Light frame follows LED indicators Red yellow green Reading MIFARE Classic UID Reading MIFARE Plus SL1 SL3 UID Reading MIFARE DESFire EV1 UID The card readers are delivered in this default mode This mode can be altered with the Configuration Card Creation Tool 3CT which enables for required settin...

Page 18: ...der to a RIM DRI ERI the card reader and bus address is automatically configured as follows 1 The first powered up card reader gets bus address 1 2 The secondly powered up card reader gets bus address 2 and so forth When the card reader is first powered the yellow LED flashes The flashing lights stop when it is correctly configured to SiPass integrated This can be tested by holding a card in close...

Page 19: ...7 Connecting card reader to SiPass integrated 19 Siemens Switzerland Ltd 2017 07 14 ...

Page 20: ...overed by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment For more detailed information about disposal of your old appliance please contact your city office waste disposal...

Page 21: ...184 95 114 60 16 85 86 12 5 12 14 42 5 42 2 5 5 Scale 1 1 Units mm ...

Page 22: ...belstrasse 22 6300 Zug Switzerland www siemens com security solutions 2017 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice Supply subject to availability Document Nr A 100010 9 Edition Date 2017 07 14 ...

Page 23: ...VR40S MF VR10S MF VR10S MF VR40S MF Installation and Mounting Version 9 0 Vanderbilt International IRL Ltd ...

Page 24: ...nd in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100224 9 ...

Page 25: ...connecting 9 5 1 Surface mounted reader 10 5 2 Surface mounted reader with cables fed from outside 11 5 3 Back box mounted reader 13 5 4 Back box mounted reader with adapter plate 14 5 5 Connecting the cables 15 5 6 Disassembling the reader 17 6 Default settings 18 7 Connecting card reader to SiPass integrated 19 7 1 Setting the card reader address 19 8 Disposal 21 ...

Page 26: ...n from neither the reader nor the system they are connected to can be extracted They are made of hardwearing materials and will endure most weather conditions The readers are easy to mount and connect and can be mounted on a flat surface or partly inside a back box They can be cleaned with most kind of domestic detergents Both readers have a multicolour light frame The VR40S MF has a keypad and a ...

Page 27: ...en 1 x Buzzer Multicolor light frame Keypad No Yes Display No Yes graphic monochrome OLED Operating temperature 40 C to 55 C 40 C to 55 C IP rating IP55 IP55 IK class 08 08 Housing Zinc casted metal bezel with polycarbonate plastic front Zinc casted metal bezel with polycarbonate plastic front Color Black matt chrome Black matt chrome Dimensions W x H x D Surface mounted 85 x 114 x 22 Back box mou...

Page 28: ...requirements and other relevant provisions of Radio Equipment Directive 2014 53 EU The EC Declaration of Conformity is available from your Vanderbilt sales office or Vanderbilt International IRL Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin 17 Ireland 3 2 FCC statements 6 Vanderbilt International IRL Ltd 2017 07 14 Model No VR10S MF VR40S MF FCC ID 2AHDLNGCR 2AHDLNGCR This device c...

Page 29: ... components 4 Reader components 1 Hinge 6 Screw for removal from wall tamper protection 2 Base 7 Front 3 Cord gasket 8 Back box plate 4 Knock outs x 4 5 Tamper base 7 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 30: ...4 Reader components 1 Screws for back box plate 2 Connector 3 Opening tool please note that this is a symbolic depiction of the opening tool 8 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 31: ...ify the parts which are needed for the appropriate alternative Please refer to respective page for l Surface mounted reader on the next page the reader is mounted on the base which first is fastened on a wall l Surface mounted reader with cables fed from outside on page 11 the reader is mounted on the base and the cables are connected via one of the knock outs l Back box mounted reader on page 13 ...

Page 32: ...ll be pushed through this hole 2 Attach the base to the wall with three screws one in the middle at the top of the base and two in the corners at the bottom of the base 3 In case that the removal from wall tamper protection is required fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 4 Continue to follow the instructions Conn...

Page 33: ... the knock outs the cables should be fed through 3 Insert the flat head screw driver in the pocket of the knock out 4 Hammer the screw driver handle This will create enough pressure to crack the exact area of the base which will release the knock out 5 Tilt the knock out with the screwdriver 6 Pull the knock out away from the base 11 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 34: ... fix the screw into the hole under the tamper base Ensure to not use excessive force since this can damage the tamper base 9 Feed the cables through the opening and reinsert the cord gasket Proceed to the instructions for Connecting the cables on page 15 It is recommended to seal the gap which the knock out creates Please note that a reader with a removed knock out is not IP 55 12 Vanderbilt Inter...

Page 35: ...ch the extra screws at the lower part of the back box plate in order to prevent rotation Use only the screws included in the packet for the lower part of the base since those ensure that the reader front will fit perfectly to be securely fitted over the back box 3 Continue to follow the instructions for Connecting the cables on page 14 13 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 36: ...icators on the connector and the base A B 2 Snap the connector in place 3 Push the cables back 4 On the backside of the front there is an EOL jumper used for RS485 bus ter mination see illustration By default the reader has the termination ON and acts as the last reader on the bus But if it is an intermediate reader on the bus the jumper must be removed or placed in OFF position 5 Place the front ...

Page 37: ...5 Mounting and connecting 6 Fold the front down until the snap lock confirms a secure attachment 15 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 38: ...fully insert the opening tool in the slot between the base and the front 2 Push gently and lift the front of the base To remove the connector 1 Insert the opening tool as indicated on the picture 2 Push down gently and tilt the connector away from the base 16 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 39: ...ivation are possible Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 Light frame follows LED indicators Red yellow green Reading MIFARE Classic UID Reading MIFARE Plus SL1 SL3 UID Reading MIFARE DESFire EV1 UID The card readers are delivered in this default mode This mode can be altered with the Configuration Card Creation Tool 3CT which enables for required settings to...

Page 40: ...o a RIM DRI ERI the card reader and bus address is automatically configured as follows 1 The first powered up card reader gets bus address 1 2 The secondly powered up card reader gets bus address 2 and so forth When the card reader is first powered the yellow LED flashes The flashing lights stop when it is correctly configured to SiPass integrated This can be tested by holding a card in close prox...

Page 41: ...7 Connecting card reader to SiPass integrated 19 Vanderbilt International IRL Ltd 2017 07 14 ...

Page 42: ...ed by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment For more detailed information about disposal of your old appliance please contact your city office waste disposal ser...

Page 43: ...184 95 114 60 16 85 86 12 5 12 14 42 5 42 2 5 5 Scale 1 1 Units mm ...

Page 44: ...ness and Technology Park Clonshaugh Dublin 17 Ireland www vanderbiltindustries com 2017 Copyright by Vanderbilt International IRL Ltd Data and design subject to change without notice Supply subject to availability Document Nr A 100224 9 Edition Date 2017 07 14 ...

Reviews: