AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202
Page 35 of 120
27.04.2006
VEXT
See note 1
TXD0/TXD1/RTS0/RTS1/DTR0 (driven by the application)
Interface pins
Undefined
Defined
PWR_IND
CTS0/CTS1/DSR0/DTR0
Figure 8: Signal states during turn-off procedure
Note 1: Depending on capacitance load from host application
3.3.3.2
Leakage Current in Power-Down Mode
The leakage current in Power-down mode varies depending on the following conditions:
•
If the supply voltage at BATT+ was disconnected and then applied again without starting
up the AC75 module, the leakage current ranges between 90µA and 100µA.
•
If the AC75 module is started and afterwards powered down with AT^SMSO, then the
leakage current is only 50µA.
Therefore, in order to minimize the leakage current take care to start up the module at least
once before it is powered down.