Administration
A31003-D3000-M100-01-76A9, 02-2013
96
OpenScape Desk Phone IP, Phone Administration, Administrator Documentation
System Settings
Administration via WBM
System > SIP interface
Related Topics
3.5.9.2 Response Timer
The
Response Timer
resp.
Call trans.
timer is started whenever the phone
sends a new INVITE message to the SIP server.
If the call transaction timer expires before the phone gets a response from the SIP
server, the phone assumes that the server had died and then attempts to contact
the backup server, if configured. If there is no backup server configured, the
phone just tidies up internally.
The data is given in milliseconds. The default value is 32 000; for OpenScape
Voice, the recommended setting is 3.7 seconds (3700 ms).
Administration via WBM
System > SIP interface