5
Level 1
PASS WORD
CHNG PSWD
NETW SELN
NEW PSWD
LEVL
Display
Condition
Password
Change
Password
Network
Selection
New
Password
Level
Indication
Parameter
1000 (PW1) ;
2000 (PW2)
NO
3P4W
0
LEVL 1
Default Value
0000 – 9998
YES / NO
3P4W / 3P3W /
1P2W / 2P2W
0000 – 9998
–
Range
CT SEC
CT PRIM
PT SEC
PT PRIM
PHSE COMP
Only Valid for
1P2W & 2P2W
TH VOLT
NOM VOLT
CT Secondary
CT Primary
PT Secondary
PT Primary
Phase
Compensation Angle
Threshold
Voltage
Nominal
Voltage
Auto
Initialization
AUTO INIT
5A
5A
350V
350V
0
0%
For 1P2W/3P4W-240V
For 3P3W/2P2W-415V
YES
1A / 5A
1A / 5A-9999A
100V – 500V
100V to 500KV
0, 90, 120,
210, 240, 330
0 – 100%
50 – 440V
YES / NO
Display
Condition
Parameter
Default Value
Range
Relays Count
Control Mode
Target
Power Factor
Step time
Discharge Time
(Reconnection
time)
Control
Sensitivity
settings
Slave ID
RLY CNT
CNTL MODE
TRGT PF
STEP TIME
DSHG TIME
SLVE ID
CNTL SENS
12
Auto
1.000
5 S
180 S
1
60%
1 – 12 / 14
Auto / Manual
0.800 to -0.800
1 S to 999 S
1 S to 9999 S
001 – 255
55% to 100%
Parity
Baud Rate
Stop Bits
Backlight
Low Current
PAR-ITY
BAUD RATE
STOP BITS
BACK LGHT
Low Curr
NONE
9600
1
0
0
NONE / ODD /
EVEN
300/600/1200/
2400/4800 /
9600/19K2
1 or 2
0 to 7200 Sec
0-50%
Level 3 accessible
only when control
mode is manual
Switching
Program
SWNG PROG
Auto
Auto / Linear /
Rotational
Level 2
Refer only if trip time setting is ON
else all tripping are instantaneous
Over Voltage setting
Under Voltage
Under Voltage setting
Total Harmonic Distortion
Over Compensate
Under Compensate
Step Error
Step Error Setting
STEP ERR
STEP ERR.S
CT Polarity error
Hysteresis voltage
Hysteresis PF
Factory Default
Reset Energy Pass word
THD I Range
Reset Energy
Reset kWh
Reset kVAh
Reset kVArh
Over Temperature
SET O.VLT
UNDR VOLT
SET U.VLT
THDI ERR
OVER COMP
UNDR COMP
CT ERR
TEMP RNGE
THDI RNGE
FAN SET
HYS VOLT
HYS PF
FACT DFLT
RSET ENGY
RSET ENGY
RSET kWh
RSET kVAh
RSET VArh
OVER TEMP
190V (L-N)
340 (L-L)
OFF
260V (L-N)
460 (L-L)
ON
OFF
ON
ON
20
ON
65 C
OFF
OFF
2
1
NO
NO
NO
NO
NO
2001
OFF
All capacitor banks are blocked
Disconnect All steps
(For Nominal Voltage)
Prompted only if over TEMP is off
FAN ON
Only Valid if customer wants
to reset energy
5min
5min
Inst
5min
5min
NA
Inst
5min
2.5min
1min
Inst
1min
1min
NA
Inst
50 - 240V (L-N)
85 - 415 (L-L)
ON / OFF
50 - 277V (L-N)
85 - 480 (L-L)
ON / OFF
ON / OFF
ON / OFF
ON / OFF
20 to 80%
ON / OFF
0-100
ON / OFF
ON / OFF
1 to 10%
1 to 5%
20 - 100%
50%
YES / NO
YES / NO
YES / NO
YES / NO
YES / NO
0001 – 9999
ON / OFF
Name of Parameter
No Voltage Release
Trip time setting
TRIP TIME
Over Voltage
Nomenclature
Default Value
Range
NO VOLT
OVER VOLT
ON
OFF
When any phase is missing
Disconnect All steps
ON / OFF
ON / OFF
Activate
Deactivate
Action to be take n by A PFC
Fan Setting
Over Temperature Setting
Disconnect All steps
For resetting energy parameters user will be prompted the password. This password will be value which will be greater than the technical password by 1.
Leve l 3
Prompted
only if
mode is
set to
manual.
Name of Parameter
Default Value
Range
Condition
OFF
ON / OFF
Relay 8
OFF
OFF
OFF
OFF
ON / OFF
ON / OFF
ON / OFF
ON / OFF
Nomenclature
RLY8
RLY9
RLY10
RLY11
RLY12
RLY13
RLY14
OFF
OFF
ON / OFF
ON / OFF
Relay 14
*
*
Relay 12
Relay 11
Relay 10
Relay 9
Relay 13
*
*
Prompted
only if
mode is
set to
manual.
Name of Parameter
Default Value
Range
Condition
OFF
ON / OFF
OFF
OFF
OFF
OFF
ON / OFF
ON / OFF
ON / OFF
ON / OFF
Nomenclature
OFF
OFF
ON / OFF
ON / OFF
Relay 4
Relay 5
Relay 6
Relay 7
Relay 1
Relay 2
Relay 3
RLY4
RLY5
RLY6
RLY7
RLY1
RLY2
RLY3
*
*
13 & 14th relay will be used for control switching only when customer selects 14 relay in config. else for FAN & ALM respectively.
Fan Settings
Setting
Description
None
Fixed On
Fan output permanently off.
Fan output permanently on.
Fan output will turn on when the
temperature exceed user set value.
Temperature ON/OFF (Setting range = 0 C - 100 C)
o
o
NOTE :
2.5min
35 m sec
90 sec
•
A.INT will be update to 'NO' automatically in configure after auto initialization completion.
Reauto - Initialization will be done by only changing A.INT - Yes in configure manually.
If DI is high controller work in manual mode & if Low return to 'Auto' mode.
Recommended that number of relays not to be changed during normal operation If done so,
restart the unit.
•
•
•
•
Recommended to restart the unit if Switching program (SWP) is changed during normal operation
for proper functionality in accordance with the chosen control mode.
#
# Response time is 3-5 sec.
8 / 12 / 14
8 / 12
'8' for 7UG0571..
'12' for 7UG0572.
.
*
Not applicable for 7UG0571-1FT20
*
*
*
*