background image

Index 
  

 

Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 

48

 

Operating Instructions, 06/2014, A5E00468983-04 

 

Summary of Contents for 7NG3092-8KM

Page 1: ..._________ ___________________ ___________________ ___________________ SITRANS Accessories Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF Operating Instructions 7NG3092 8KU 7NG3092 8KM 06 2014 A5E00468983 04 Introduction 1 General safety notes 2 Description 3 Installing 4 Commissioning 5 Operating SIPROM T 6 Troubleshooting Maintenance 7 Technical data 8 Certificates 9 ...

Page 2: ...nly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens pro...

Page 3: ...nnection 7NG3092 8KU 10 3 3 2 Modem with a RS232 connection 7NG3092 8KM 10 4 Installing 11 4 1 Hardware and software requirements 11 4 2 Installing the SIPROM T parameterization software 11 4 3 Windows XP and earlier 12 4 3 1 Installing USB drivers 12 4 3 1 1 Step 1 Preparing for installation 12 4 3 1 2 Step 2 Installation of the USB modem 16 4 3 1 3 Step 3 Entries in the SIPROM T parameterization...

Page 4: ... SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 4 Operating Instructions 06 2014 A5E00468983 04 7 Troubleshooting Maintenance 41 7 1 Troubleshooting 41 7 2 Maintenance 41 8 Technical data 43 9 Certificates 45 Index 47 ...

Page 5: ...arranties or modify the existing warranty The content reflects the technical status at the time of printing We reserve the right to make technical changes in the course of further development Siemens Regional Offices If you need more information or have particular problems which are not covered sufficiently by the operating instructions contact your local Siemens Regional Office You will find the ...

Page 6: ...Introduction 1 2 Further information Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 6 Operating Instructions 06 2014 A5E00468983 04 ...

Page 7: ...TH200 temperature transmitters in a secure area and offline under laboratory conditions pollution degree 1 or 2 max Ta 30 C Any 4 to 20 mA current loop connected to the transmitter must be disconnected completely before parameter assignment The device may only be used for the purposes specified in these instructions Insofar as they are not expressly stated in these instructions all changes to the ...

Page 8: ...azardous systems Training and instruction in maintenance and use of adequate safety equipment according to safety regulations Should be trained in first aid 2 4 Laws and directives Observe the test certification provisions and laws applicable in your country during connection assembly and operation These include for example National Electrical Code NEC NFPA 70 USA Canadian Electrical Code CEC Cana...

Page 9: ...the transmitters The use of the SIPROM T parameterization software is also described WARNING This modem should only be used for parameterization of the SITRANS TH100 TH200 TR200 TF200 TF with TH200 transmitters Damage to the modem or the connected device is not ruled out otherwise 3 2 Product features Universal modem for parameterization of the SITRANS TH100 TH200 TR200 TF200 TF with TH200 transmi...

Page 10: ...an also be ordered separately Order No A5E00364512 USB B USB A cable length 200 cm The USB A connector enables a connection with a PC or with a distribution hub compliant with the USB 1 1 USB 2 0 standard We recommend using a four wire hub with a built in power supply 3 3 2 Modem with a RS232 connection 7NG3092 8KM The following is supplied with your modem for SITRANS TH100 TH200 TR200 TF200 TF wi...

Page 11: ... You require a PC with a CD ROM drive and a USB port for the USB modem or a RS232 port for the RS232 modem 4 2 Installing the SIPROM T parameterization software Introduction The enclosed mini DVD contains the SIPROM T parameterization software You can also download the parameterization software from the Internet free of charge Refer to SIPROM T software package on the Internet http www siemens com...

Page 12: ...H200 should only be connected to the PC when installation of the parameterization software has been completed Result After successful installation a new program group with the name Siemens Process Instruments is created in your Windows start menu The USB driver that you require for the USB modem is also pre installed 4 3 Windows XP and earlier 4 3 1 Installing USB drivers 4 3 1 1 Step 1 Preparing ...

Page 13: ...dem to a free USB port of your computer using the cable provided The 7NG3092 8KU modem is compatible with USB 1 x and USB 2 0 After plugging in Windows opens the Hardware wizard automatically 2 Click on the second installation option Install from a list or specific location Advanced 3 Confirm with Next The following window of the wizard appears 4 Select the options Search for the best driver in th...

Page 14: ...erization software and the USB drive were installed The USB driver is installed in the C Program Files SIPROM T USB sub directory in case of a standard installation of the SIPROM T parameterization software You must specify the appropriate path if you have installed the SIPROM T parameterization software in another directory 7 Click OK You are now directed back to the previous window and the direc...

Page 15: ... Result This completes initial preparations for the installation of the USB driver Now go to step 2 of the installation process Note Only a part of the installation is carried out at this point in time Do not abort the installation at this stage Otherwise the driver will not be installed correctly and the USB modem will not be detected by the SIPROM T parameterization software See also Installing ...

Page 16: ... 2 Installation of the USB modem Prerequisites After executing step 1 of the installation the Hardware wizard should open again automatically The following window appears Procedure Continue with the installation as specified below 1 Click on the second installation option Install from a list or specific location Advanced 2 Confirm with Next The following window opens ...

Page 17: ...eparing for installation have been accepted If not you have to make these settings afresh as described in Step 1 Preparing for installation 4 Click Next The USB driver is being installed The following window opens 5 Click Finish 6 Check whether the system has set up the correct COM port for the SIPROM T parameterization software For this purpose invoke the Control panel via Start Settings The foll...

Page 18: ...r SITRANS TH100 TH200 TR200 TF200 TF with TH200 18 Operating Instructions 06 2014 A5E00468983 04 7 Double click the System entry The following window opens 8 Click Device Manager in the Hardware tab Windows calls up the Device Manager The following window opens ...

Page 19: ...USB of your computer are displayed in this folder The newly installed USB port has the name USB Serial Port COMx where x indicates the number of this COM port It is COM3 in our example 10 Note the number of the COM port in our example 3 If it is in the range from 1 to 8 you can continue the installation with Step 3 Entries in the SIPROM T parameterization software Otherwise the COM port number mus...

Page 20: ...00 TH200 TR200 TF200 TF with TH200 20 Operating Instructions 06 2014 A5E00468983 04 11 If the COM port number is not in the range from 1 to 8 double click the marked line in Device Manager The following window opens 12 Click the Port Settings tab The following window opens ...

Page 21: ...he COM Port Number field COM numbers with the in use comment have already been occupied and can no longer be used If all COM ports are occupied one serial port must be disabled to be able to install the USB driver Please contact your system administrator in this case 4 3 1 3 Step 3 Entries in the SIPROM T parameterization software Prerequisites You should be on the Windows desktop All other proces...

Page 22: ...re The COM port number selected by you must be entered in the SIPROM T parameterization software This is done as specified below 1 Start the SIPROM T parameterization software via Start Programs Siemens Process Instruments SIPROM T The application is started and the following window opens 2 Select Communication path from the Device menu The following window opens ...

Page 23: ...irm the setting with OK Result The installation of the USB driver is completed successfully See also Step 2 Installation of the USB modem Page 16 4 3 2 Uninstalling USB drivers Introduction You can uninstall the USB driver manually if you do not wish to continue using the SIPROM T parameterization software in combination with the USB modem Note This action uninstalls only the USB driver and not th...

Page 24: ...ions 06 2014 A5E00468983 04 Procedure Uninstall the USB driver as specified below 1 Go to C Program Files SIPROM T USB in Windows Explorer if you have selected standard installation If not go to the directory in Windows Explorer where you have installed the USB driver 2 Disconnect the USB modem from the USB connection of your PC ...

Page 25: ...g window opens 4 Click Continue The following window opens 5 Click Finish Result The USB driver is uninstalled SIPROM T can no longer be operated with the USB modem The USB driver files however remain on your hard disk If you wish to use the USB modem again execute the installation process as described in Step 2 Installation of the USB driver See also Step 2 Installation of the USB modem Page 16 ...

Page 26: ... TH200 26 Operating Instructions 06 2014 A5E00468983 04 4 4 Windows 7 and higher 4 4 1 Installing USB drivers Procedure 1 Open the SIPROM T Software directory 2 Open the USB Win7 Higher folder 3 Right click on the CDM20830_Setup exe file and select Execute as administrator The following window opens ...

Page 27: ...Installing 4 4 Windows 7 and higher Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 Operating Instructions 06 2014 A5E00468983 04 27 4 Click Extract The following window opens ...

Page 28: ...ructions 06 2014 A5E00468983 04 5 Click Next The USB driver is installed The following window opens 6 Click Finish 7 Check whether the system has installed the correct COM port for the SIPROM T parameterization software To do this proceed as described in steps 6 to 11 in chapter Step 2 Installation of the USB modem Page 16 ...

Page 29: ...u do not wish to continue using the SIPROM T parameterization software in combination with the USB modem Note This action uninstalls only the USB driver and not the SIPROM T software The SIPROM T software can be used with the RS232 modem after uninstalling the USB driver Procedure Uninstall the USB driver as specified below 1 Open the Windows Device Manager 2 Select USB Serial Port COM5 under Port...

Page 30: ...Instructions 06 2014 A5E00468983 04 4 Select Uninstall from the shortcut menu The following window opens 5 Select the option box for Delete driver software for this device 6 Click OK 7 Select USB Serial Converter under Universal Serial Bus controllers in the Windows Device Manager 8 Right click on USB Serial Converter ...

Page 31: ...TF200 TF with TH200 Operating Instructions 06 2014 A5E00468983 04 31 9 Select Uninstall from the shortcut menu The following window opens 10 Select the option box for Delete driver software for this device 11 Click OK Result The associated registration entry to the USB modem is deleted ...

Page 32: ...Installing 4 4 Windows 7 and higher Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 32 Operating Instructions 06 2014 A5E00468983 04 ...

Page 33: ...y of SITRANS TH100 TH200 TR200 TF200 TF with TH200 temperature transmitters If the red LED on the SIPROM T modem is lit you must check that the modem is functioning correctly and the SITRANS TH100 TH200 TR200 TF200 TF with TH200 temperature transmitter can no longer be used in hazardous areas Note Parameterization of the SITRANS TH100 TH200 TR200 TF200 TF with TH200 transmitters may only be carrie...

Page 34: ... intended only for use in a controlled electromagnetic environment RF transmitters such as mobile phones may not be used in the immediate range 5 2 Commissioning the modem Note The input variable is digitally requested and displayed by the PC during the parameterization process The analog output current always remains constant You can use the SIPROM T parameterization software and the modem for SI...

Page 35: ... TF200 TF with TH200 Operating Instructions 06 2014 A5E00468983 04 35 Parameterization via the USB modem Parameterization via the RS232 modem Note USB modem versions Insert the USB B connector into the jack labelled USB on your modem Connect the USB A connector to a free USB port of your PC ...

Page 36: ...em Illuminates when the modem is connected to the USB port of the PC and the operating system of your PC is in the normal mode This LED switches off if the PC is in the standby or idle mode For the RS232 modem Illuminates when the supply voltage of the modem is switched on using the 6 V power adapter that is provided Comm Yellow The LED flickers while transferring data from the PC to the modem Err...

Page 37: ... menu items in brief Please refer to the online help of the SIPROM T parameterization software regarding further notes for operating this software You will find the technical details regarding the sensor characteristics of SITRANS TH100 TH200 TR200 TF200 TF with TH200 in the corresponding operating instructions You will find these operating instructions on the enclosed CD and on the Internet ...

Page 38: ...emens Process Instruments SIPROM T The splash screen of SIPROM T appears while the application is starting The following window opens as soon as the application is loaded Extras Settings Device Select whether you wish to assign parameters to SITRANS TH100 TH200 TR200 TF200 TF with TH200 Extras Settings Communication path Determine the USB or COM port that SIPROM T should use for communicating with...

Page 39: ...TF200 TF with TH200 to SIPROM T Note The current table data is overwritten View Measuring value display This menu is used for displaying the current digital value of the connected sensor Although the current value associated with the digital value is displayed the connected transmitter does not give a physical output File Save as This menu is used for saving the current table data in a file If add...

Page 40: ...Operating SIPROM T Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 40 Operating Instructions 06 2014 A5E00468983 04 ...

Page 41: ...olarities or whether the loop current is at least 3 5 mA The Comm LED does not illuminate For the USB modem Modem is not detected by the PC Check the port settings in SIPROM T Check the driver installation and reinstall SIPROM T if required For the RS232 modem RS232 not connected with the PC Connect RS232 with the PC Modem is not detected by the PC Check the COM port settings in SIPROM T The Error...

Page 42: ...Troubleshooting Maintenance 7 2 Maintenance Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 42 Operating Instructions 06 2014 A5E00468983 04 ...

Page 43: ...y AC 90 265 V 50 60 Hz max 6 W USB port relevant only for the USB version USB version USB 1 1 compatible with USB 2 0 USB current Standard 100 mA Power supply of the transmitter Available power supply Max 18 mA Available supply voltage Max 15 V at 4 mA Ambient conditions Range of ambient temperature 0 C 30 C 32 F 86 F Range of storage temperature 20 C 65 C 4 F 149 F Relative humidity 5 to 80 at 25...

Page 44: ...Technical data Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 44 Operating Instructions 06 2014 A5E00468983 04 ...

Page 45: ...0 TR200 TF200 TF with TH200 Operating Instructions 06 2014 A5E00468983 04 45 Certificates 9 You will find these certificates on the enclosed CD and on the Internet See also Certificates http www siemens com processinstrumentation certificates ...

Page 46: ...Certificates Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 46 Operating Instructions 06 2014 A5E00468983 04 ...

Page 47: ...n 5 Siemens regional offices 5 L LED 36 LEDs 36 Limitation of use 9 M Menus 37 More information 5 O Operating systems 11 Operation SIPROM T parameterization software 37 P Parameterization 35 Parameterization software 11 17 22 Operation 37 Product information on the Internet 5 R RS232 modem Scope of delivery 10 S Scope of delivery RS232 modem 10 USB modem 10 Siemens Regional Office 5 SIPROM T Opera...

Page 48: ...Index Modem and SIPROM T for SITRANS TH100 TH200 TR200 TF200 TF with TH200 48 Operating Instructions 06 2014 A5E00468983 04 ...

Reviews: