![Siemens 6SL3210-1PE21-1AL0 Manual Download Page 53](http://html.mh-extra.com/html/siemens/6sl3210-1pe21-1al0/6sl3210-1pe21-1al0_manual_377045053.webp)
Siemens PM240-2_EN_rev00-30082019.docx
10-3
-
Parameter display
Press the "P" key.
The required parameters can be selected using the arrow keys.
Press the "FN" key
"r00000" is displayed
Press the "P" key
changes back to the operating display
Parameter display
The parameters are selected in the BOP20 using the respective identification number (Pxxxxx).
The parameter display is reached from the operating display by pressing the "P" key.
Parameters can be searched for using the arrow keys.
The parameter value is displayed by pressing the "P" key again.
You can toggle between the drive objects by simultaneously pressing the "FN" key and an arrow key.
You can toggle between "r00000" and the parameter that was last displayed by pressing the "FN" key in the
parameter display.
Figure 34 Parameter display
Drive objects:
01: Control Unit (CU)
02: Drive
03: Other objects
(es: P0013[0])