System diagnostics
9.2 XML/PLC error messages
SIMATIC RF600
476
System Manual, 06/2019, J31069-D0171-U001-A22-7618
""ER"
L
LED
X
XML/
L
LED
((hex)
P
PLC block
((hex)
E
Error description
2 Hz
0x54
0xE5FE04
Invalid data block number (DBN) on the reader/communications module
--
0x55
0xE5FE05
Invalid data block number (DBN) in the Ident profile
2 Hz
0x56
0xE5FE06
Invalid data block length (DBL) on the reader/communications module
--
0x57
0xE5FE07
Invalid data block length (DBL) in the Ident profile
2 Hz
0x58
0xE5FE08
The previous command is still active or the buffer is full.
A new command was sent to the reader or communications module although the last com-
mand is still active.
x
The active command can only be aborted with "INIT".
x
Before a new command can be started, "DONE bit = 1" must be set (exception: "INIT").
x
Two Ident profile calls had the same "HW_ID", "CM_CHANNEL" and "LADDR" parame-
ter settings.
x
Two Ident profile calls are using the same pointer.
x
After eliminating the error, an "INIT" must be executed.
x
When working with command repetition (e.g., fixed code transponder), no data is being
fetched from the transponder. The data buffer on the reader/communications module
has overflowed. Transponder data has been lost.
--
0x59
0xE5FE09
The reader/communications module runs a hardware reset ("INIT_ACTIVE" set to "1"). The
Ident profile expects an "INIT" (bit 15 in the cyclic control word).
--
0x5A
0xE5FE0A
The "CMD" command code and the relevant acknowledgement do not match. This can be a
software error or synchronization error that cannot occur in normal operation.
--
0x5B
0xE5FE0B
Incorrect sequence of acknowledgement frames (TDB / DBN)
--
0x5C
0xE5FE0C
Synchronization error (incorrect increment of AC_H / AC_L and CC_H / CC_L in the cyclic
control word). "INIT" had to be executed.
--
--
0xE5FE81
Communications error between reader and communications module
Access denied
--
--
0xE5FE82
Communications error between reader and communications module
Resource is occupied
--
--
0xE5FE83
Communications error between reader and communications module
Functional error of the serial interface
--
--
0xE5FE84
Communications error between reader and communications module
Other faults/errors
2 Hz
0x61
0xE6FE01
Unknown command
An uninterpretable XML command was sent to the reader or the Ident profile sends an
uninterpretable command to the reader.
Possible causes:
x
The "AdvancedCmd" block was supplied with an incorrect "CMD".
x
The "CMD" input of the "AdvancedCmd" block was overwritten.
--
0x62
0xE6FE02
Invalid command index (CI)