background image

Industrial I/O-Node - ION PROFIBUS DP SPY T001 

SIPLUS CMS4000

 

Manual - English 
A5E02186042 

 2 / 23

 

Safety Guidelines

 

This document contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. The 
notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only 
have no safety alert symbol. 

 

Danger 

indicates an 

imminently

 hazardous situation which, if not avoided, will result in death or serious injury.

 

 

Warning 

indicates a 

potentially

 hazardous situation which, if not avoided, could result in death or serious injury.

 

 

Caution 

used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or mod-
erate injury.

 

 Caution 

used without safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property dam-
age.

 

 Notice 

used without the safety alert symbol indicates a potential situation which, if not avoided, may result in an undesirable result or 
state.

 

When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a notice refers to personal 
damages with the safety alert symbol, then another notice may be added warning of property damage. 

Qualified Personnel 

The device/system may only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to 
install and work on the equipment. Qualified persons are defined as persons who are authorized to commission, to earth, and to tag cir-
cuits, equipment and systems in accordance with established safety practices and standards. 

Intended Use 

Please note the following: 

 

Warning 

This device and its components may only be used for the applications described in the catalog or technical description, and 
only in connection with devices or components from other manufacturers approved or recommended by Siemens. 

This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and 
maintained as recommended.

 

Trademarks 

All designations marked with ® are registered trademarks of Siemens AG. Other designations in this documentation might be trademarks 
which, if used by third parties for their purposes, might infringe upon the rights of the proprietors. 

Copyright Siemens AG 2009. All rights reserved. 

Reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be 
liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.

 

Disclaimer of Liability

 

We have checked the contents of this document for agreement with the hardware and software described. Since deviations cannot be 
precluded entirely, we cannot guarantee full agreement. However, the data in the manual are reviewed regularly, and any necessary cor-
rections will be included in subsequent editions. Suggestions for improvement are welcomed. 

 
Siemens AG 
Industry Sector 
P.O. Box 4848 
90327 Nuremberg 
Germany 

Siemens AG 2009

Technical data subject to change

Summary of Contents for 6AT8000-1BA00-5XA0

Page 1: ...02186042 1 23 Preface 1 Scope of Delivery 2 SIPLUS CMS4000 Product Characteristics 3 Industrial I O Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000 1BA00 5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Manual English Release 2009 09 Contact Information 8 ...

Page 2: ...e equipment Qualified persons are defined as persons who are authorized to commission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with device...

Page 3: ...ents 7 3 2 1 Hardware 7 3 2 2 Software 7 3 3 Order Numbers 7 3 4 Network Topology 8 3 5 Interfaces 9 3 5 1 Overview of Interfaces 9 3 5 2 IEEE1394a Interfaces 10 3 5 3 Power Supply Interface 11 3 5 4 Fieldbus Interface 12 3 6 Indicators 13 3 7 Technical Data 14 3 8 Block Diagram 16 4 Installation and Maintenance 17 4 1 Types of Installation 17 4 2 Installation 17 4 3 Disassembly 18 4 4 Example of ...

Page 4: ...ument is valid for the following device ION PROFIBUS DP SPY T001 1 3 Audience This document is intended for personnel involved in the commissioning and using of the device ION PROFIBUS DP SPY T001 1 4 Standards and Approvals The device ION PROFIBUS DP SPY T001 meets the requirements of the CE mark Extended information can be found in the appendix of this manual Note The particularized approvals ar...

Page 5: ...pe of Delivery What is shipped Device ION PROFIBUS DP SPY T001 3 pin plug in terminal block PHOENIX CONTACT COMBICON 3 Pin MVSTBW 2 5 3 STF 5 08 2 2 Unpacking and Checking After unpacking please check the packet for completeness and all parts for transport damage Warning Do not use any parts that show evidence of damage ...

Page 6: ... ION PROFIBUS DP SPY T001 captures all of the data which is exchanged in between of any two devices which are present at the attached PROFIBUS DP bus and transmits the measured data to a superior industrial PC via its FireWire IEEE1394a standard link with 400 Mbps The device is designed for the usage on a DIN rail ION PROFIBUS DP SPY T001 ...

Page 7: ...IEEE1394 Ethernet and USB interfaces power supply units and connecting cables depending on the used SIPLUS CMS4000 components 3 2 2 Software CASTOMAT X Tools XP Standard or Professional Edition 3 3 Order Numbers Article Order Number MLFB ION PROFIBUS DP SPY T001 6AT8000 1BA00 5XA0 User Documentation http support automation siemens com X Tools Standard Edition 6AT8000 0AB00 1BA0 X Tools Professiona...

Page 8: ... is equal to the one of a bus with branching but without loops Tree topology The tree topology facilitates the building of networked systems by connecting two further nodes to each node tree topology Chain topology The chain topology enables the building of networked systems by connecting one further node to each node chain topology Caution The maximum number of nodes per bus is limited to 63 The ...

Page 9: ...0 Manual English A5E02186042 9 23 3 5 Interfaces 3 5 1 Overview of Interfaces The device ION PROFIBUS DP SPY T001 provides three plugs for further SIPLUS CMS4000 components and one interface to connect the fieldbus solution PROFIBUS DP ION PROFIBUS DP SPY T001 ...

Page 10: ... English A5E02186042 10 23 3 5 2 IEEE1394a Interfaces At the ION PROFIBUS DP SPY T001 the IEEE1394a Interfaces P1 P2 P3 are implemented as 6 pin sockets IEEE1394a Interfaces Caution Only cables of a maximum length of 4 5 m may be connected to the IEEE1394a Interfaces ...

Page 11: ... 90 seconds the device starts automatically again power supply interface Caution The device ION PROFIBUS DP SPY T001 is designed for operation with safety extra low voltage This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals The power supply unit for the supply of the ION PROFIBUS DP SPY T001 has to meet NEC Class...

Page 12: ...ROFIBUS DP SPY T001 SIPLUS CMS4000 Manual English A5E02186042 12 23 3 5 4 Fieldbus Interface At the ION PROFIBUS DP SPY T001 the interface of the fieldbus solution PROFIBUS DP is implemented as a SUB D socket fieldbus interface ...

Page 13: ...K Description indicator for the connection to the controller Color yellow Condition off no connection to the controller on connection to the controller established blinks data exchange with the controller Name COM Description data transfer indicator Color green Condition off firmware does not operate on firmware operates Name BUS Description operating mode indicator Color green Condition off no da...

Page 14: ...input Input voltage 18 32 VDC Typ Power loss at 24 VDC 12 W Typ Current consumption at 24 VDC 0 5 A IEEE1394a Interface P1 P3 Number 3 Connector type 6 pin socket Type IEEE1394a interface Transfer speed 400 Mbps Standard IEEE1394a Fieldbus Interface BUS Number 1 Connector type SUB D socket Type PROFIBUS DP interface Transfer speed 9 6 19 2 45 45 93 75 187 5 500 kbps 1 5 3 6 12 Mbps Operation mode ...

Page 15: ...ature during operation 0 55 C Transportation and storage temperature 25 85 C Humidity rating 5 95 not condensing EMC interference emission EN 55011 2007 Class A EMC interference immunity EN 61000 6 2 2005 Degree of protection IP20 Constructive Structure Dimensions H x W x D in mm 200 x 60 2 x 126 5 Design aluminum stainless steel Color silver Weight 1 kg Mounting DIN rail profile DIN EN 50022 35x1...

Page 16: ...FIBUS DP SPY T001 SIPLUS CMS4000 Manual English A5E02186042 16 23 3 8 Block Diagram block diagram PROFIBUS DP Interface FPGA Link Layer Physical Layer FIFO CTRL Logic µC FPGA IEEE1394a Power Supply 24 VDC PROFIBUS DP PROFIBUS DP ...

Page 17: ...the device on the DIN rail and push it down towards the DIN rail so that it snaps in Installation of electric connection cables Install the plug of the PROFIBUS DP connection cable Install the plugs of the IEEE1394 connection cables Install the terminal block of the power supply connection cable installation of the ION PROFIBUS DP SPY T001 on a DIN rail Caution The spaces which are specified in ch...

Page 18: ...les Disassemble the terminal block of the power supply connection cable Disassemble the plugs of the IEEE1394 connection cable Disassemble the plug of the PROFIBUS DP connection cable Removal of the device from the DIN rail Push the device down against the DIN rail and hang it out disassembly of the ION PROFIBUS DP SPY T001 from the DIN rail 1 2 3 ...

Page 19: ... Note This image shows an exemplary installation Technical data subject to change 4 5 Grounding The screw on the front side of the device is provided as grounding connection 4 6 Maintenance If a fault develops please send the device to the Siemens logistics center Address SIEMENS AG I IA RETOUREN CENTER FUERTH SIEMENSSTR 2 90766 FUERTH GERMANY ...

Page 20: ...es as de scribed in this commissioning manual Conformity Certificates The EC Declaration of Conformity is available for the responsible authorities according to the abovementioned EC Directive at the following address SIEMENS AG I IA SE DE WUERZBURGER STR 121 90766 FUERTH GERMANY Notes for the Manufacturers of Machines This product is not a machine in the sense of the EC Machinery Directive There ...

Page 21: ...Industrial I O Node ION PROFIBUS DP SPY T001 SIPLUS CMS4000 Manual English A5E02186042 21 23 6 References 6 1 Other Documentation SIPLUS CMS4000 User Documentation ...

Page 22: ...does not contain complete detail information to the product due to reasons of clarity and can therefore exclude each thinkable case of assembly usage or the maintenance Further information is obtained from your local Siemens office and from the homepage http www siemens de siplus cms Technical data subject to change In cases of doubt the German document is valid ...

Page 23: ... O Node ION PROFIBUS DP SPY T001 SIPLUS CMS4000 Manual English A5E02186042 23 23 8 Contact Information Address SIEMENS AG I IA SE DE WUERZBURGER STR 121 90766 FUERTH GERMANY Internet http www siemens de siplus cms ...

Reviews: