Siemens 5WG1205-2AB21 Manual Download Page 4

4
Siemens

Datasheet

A6V11980238_en--_a

Smart Infrastructure

2021-01-28

Mechanical design

The device consists of the following parts:

  Touch panel with electronics, operating elements and built-in room temperature sensor

  Mounting plate is an additional part to complete the installation for 5WG1205-2AB21

Operation and display

No.

Product description

No.

Product description

  Display and touch operation area

 

Micro SD card slot

②③

  Proximity sensor

 

KNX bus connection terminal

  Color light strip

 

Built-in temperature sensor

Auxiliary power supply connection

terminal

Note

  Entering programming mode:

–  Click the setting icon

 in home page;

–  Goes to “General”;
–  Enable "KNX programming", then the colorful strip turns red and device can be

configured via ETS.

  KNX programming function need to be done by professional engineers. Make sure this

function is disabled during daily operation and if it is enabled:
–  The device can operate normally.
–  The color strip is constant red and it affects the strip life span.

  Micro SD card is used for modifying the background picture, electronic photo album,

icons for home page or multi-functional pages. SDHC card and FAT32 format are only

supported and the capacity of Micro SD cards is not greater than 32 GB.

Summary of Contents for 5WG1205-2AB21

Page 1: ...ontroller and or ventilation Interface and operation for VRF devices VRF Variable Refrigerant Flow Display of temperature humidity air quality energy metering value etc Schedule event management and basic logic function Configurable navigation for up to 15 function pages Administrator function via password or bus objects Proximity sensor adjustment of screen brightness buzzer Customization possibl...

Page 2: ...ff and Auto operation mode changes 4 modes Comfort Standby Economy and Protection VRF Variable Refrigerant Flow interface allows TC5 to act as the user interface to operate VRF or VRV Variable Refrigerant Volume air conditioning devices with a VRF gateway Enhanced floor heating control has dedicated timer and scene function There is indication of heating valve on off and timer operation on screen ...

Page 3: ...No Product Description 1 Mounting plate For fitting onto a conduit box 1 2 Screws 2 Only for China market Note 1 Conduit box needs to be ordered separately 2 6 32 flat head machine screw is for US market Ordering When ordering specify product quantity product number stock number and name e g UP 205 21 5WG1205 2AB21 5 touch panel Product documentation Title Document ID Mounting instructions A6V1198...

Page 4: ...ensor Auxiliary power supply connection terminal Note Entering programming mode Click the setting icon in home page Goes to General Enable KNX programming then the colorful strip turns red and device can be configured via ETS KNX programming function need to be done by professional engineers Make sure this function is disabled during daily operation and if it is enabled The device can operate norm...

Page 5: ... device Wiring Equipped with protective features against over voltage over current short circuit and reverse polarity in the power supply All connectors must be soldered using tin wires Otherwise resistance will be generated in the contacts over time which cause unstable operation The device is powered with direct current Avoid reversing the positive and negative poles of the power supply When con...

Page 6: ... accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of ...

Page 7: ...ree of housing as per EN 60529 IP30 Environmental conditions Storage EN 60721 3 1 Class 1K3 Temperature 25 55 C Humidity 0 93 r h non condensing Transport EN 60721 3 2 Class 2K3 Temperature 25 70 C Humidity 0 93 r h non condensing Operation EN 60721 3 3 Class 3K5 Temperature 5 45 C Humidity 0 93 r h non condensing Mechanical conditions Storage EN 60721 3 1 Transport EN 60721 3 2 Operation EN 60721...

Page 8: ...tained based on human detection not an obstacle Built in temperature sensor Measuring accuracy at 25 C NTC 100k 1 K Display 5WG1205 2AB21 5 inch color capacitance touch screen 480 854 pixel Dimensions mm w h d 5WG1205 2AB21 86 148 8 32 5 Weight without with package 5WG1205 2AB21 192 376 g Materials and colors 5WG1205 2AB21 Rear housing PC V0 Front panel 6063 aluminum Touch panel Glass Film Film ...

Page 9: ...9 Siemens Datasheet A6V11980238_en _a Smart Infrastructure 2021 01 28 Diagrams Connection terminals DC DC Auxiliary power voltage DC 24 30 V KNX KNX KNX operating voltage DC 21 30 V ...

Page 10: ...to change without notice Document ID A6V11980238_en _a Edition 2021 01 28 Dimensions mm Support Hand over the operating instructions and all other technical product information to the client Return faulty devices with a return delivery note to the local Siemens office For technical questions contact 49 911 895 7222 49 911 895 7223 support automation siemens com http www siemens com supportrequest ...