background image

-4-

-5-

Low ba ery mode

When the ba ery is running low, the smoke alarm will indicate this with a 
repe

ve beep and flash for approximately 30 days. WARNING: This smoke 

alarm is equipped with a non-replaceable ba ery. When this warning occurs, 
replace the device as soon as possible! The acous c low ba ery warning 
signal can be muted for ten hours by pressing the test bu on. The smoke 
alarm is s ll func oning and able to detect smoke when it's in this mode.

Fault warning mode

When the smoke alarm is not func oning properly, it will turn into the fault 
warning mode. Try cleaning the smoke alarm (see paragraph “Maintenance“) 
or replace the smoke alarm!

Maintenance

Test this smoke alarm weekly for correct opera on using the test facility. If 
the smoke alarm func ons correctly, it will generate a loud beep. Due to 
the loudness of the alarm, make sure that you always stand at arm’s length 
distance from the unit when you are tes ng. If the smoke alarm does not 
generate an acous c signal, the smoke alarm must be replaced 
immediately!

Clean the smoke alarm at least once per month to remove dirt, dust or 
debris. Use a vacuum cleaner with a so  brush and vacuum all sides and 
covers of the smoke alarm. Do not remove the top cover of the smoke 
alarm to clean it inside. 

Do not a empt to repair this smoke alarm. If the smoke alarm shows a 
damage related to its func onality, it must be replaced!

Trouble shoo ng: False alarm is o en caused by dust or steam. 

Recycling and disposal 

        The WEEE symbol means that this product and ba eries must be 
       

 

disposed separately from other household waste.  When they reach 

        their end of life, take them to a designated waste collec on point in 
your area to guarantee a safe disposal or recycling. Ba eries must be removed 
from the product by a qualified person, by opening the product. Protect the 
environment, human health and natural resources!

EN

SMOKE ALARM 

User manual

5TC1292-7

Transport

Product is classified as a dangerous good, observe dangerous goods 
regula ons!

      

h p://www.siemens.com/lowvoltage/dangerousgood

h ps://support.industry.siemens.com

     

Note: During the transport, the product must be deac vated. Remove the 
moun ng plate from smoke detector for deac va on.

Service

Cer fied by AFNOR Cer fica on (www.afnor.org). For advise from experts and 
firefighters, go to: h ps://cer fica on.afnor.org/securite/nf- securite-
incendie-domes que. 

The CE mark affixed to this product confirms its compliance with the 
European Direc ves which apply to the product and, in par cular, its 
compliance with the harmonized specifica ons of standard EN 14604:2005 
rela ng to Construc on Products Regula on 305/2011.
The NF – DOMESTIC FIRE SAFETY mark provides assurance as to safety and 
consistent quality inspected by experts. Through its rigorous and exhaus ve 
inspec ons (holder's quality management system, product inspec ons, audits 
and monitoring tests, etc.), the NF mark represents a comprehensive 
guarantee for consumers that the cer fied products are compliant. The NF – 
DOMESTIC FIRE SAFETY mark confirms the product's compliance with 
cer fica on rules NF 292.

ESSENTIAL CHARACTERISTICS: PASS
Nominal ac va on condi ons / sensi vity / response delay (response  me) 
and performance under fire condi ons - Opera ng reliability - Tolerance to 
supply voltage - Durability of opera onal reliability and response delay, 
temperature resistance, vibra on resistance, humidity resistance, corrosion 
resistance, electrical stability.

Siemens AG 
Siemensstr. 10 
D93055 Regensburg (Germany)
www.siemens.com         

Iden fica on

Type of moun ng                                             Ceiling

Main power supply                                        Internal to the device (ba ery)

Ba ery dura on of the 
main power supply                                         10 years, seal not replaceable

Individual alarm indicator                            Yes

Suitable for installa on in 
recrea onal vehicles                                      Yes

Alarm silence facility                                      Yes

Ba ery fault-forwarding at night             Yes

Essen al cer fied features covered by the NF mark

  

                        20          5TC1292-7

            0333     Smoke Alarm

            EN 14604:2005 + AC:2008

DoP: 70782A-WA-DoP

h ps://support.industry.siemens.com     

  Opera ng mode       Visual signal (flash)                     

Acous c signal (beep)                 

Descrip on mode

  Normal              1 x per 40 seconds                       

None                             

 Device is func oning properly

  Test                 1 x per second (3 x), pause of 1,5 seconds     

1 x per second (3 x), pause of 1,5 seconds   

 Device is being tested             

  Alarm               1 x per second (3 x), pause of 1,5 seconds     

1 x per second (3 x), pause of 1,5 seconds   

 Device has detected smoke

  Alarm silence         1 x per 8 seconds                      

None                             

 Smoke alarm is muted

  Low ba ery           1 x per 40 seconds (simultaneously with beep) 

1 x per 40 seconds (simultaneously with flash) 

Ba ery is running low             

  Low ba ery silence     1 x per 40 seconds                     

None                             

 Low ba ery warning is muted

  Fault warning         1 x per 40 seconds (alterna ng  with beep)    

1 x per 40 seconds (alterna ng with flash)   

Device is not func oning properly

Overview visual & acous c signals

R0

Reviews: