Functions
6.5 Overload protection
Motor starter (3RK1308‑0**00‑0CP0)
78
Equipment Manual, 11/2019, A5E34821005002A/RS-AC/003
Response to overload - thermal motor model
You use this device parameter to specify how the motor starter is to respond to overload:
●
Trip without restart
●
Trip with restart
WARNING
Hazardous Voltage.
Can Cause Death, Serious Injury, or Property Damage.
When the cooling time has expired following an overload trip, and a RESET takes place,
or automatic restart has been parameterized, the machine starts up immediately if a
control command is active. People in the danger area may be injured.
Make sure that the danger area of the machine is kept clear of people.
●
Warning: a general warning is set.
In ATEX operation, you can only parameterize fail-safe motor starters to
"Trip without restart".