Hoses for the cooling system
The hoses for the cooling system must be highly resistant to the coolant, flexible, and
abrasion proof. The hoses for the cooling system should not be chosen until all the materials
used in the cooling system and the applicable boundary conditions are known.
When using a cooling connection adapter with motors featuring integrated cooling, overly
thin hoses should not be used directly following the cooling connection adapter in order to
prevent pressure drops.
For a list of companies from whom you can obtain connectors and accessories for cooling
systems, see the appendix.
Note
We cannot guarantee the composition, nature, state, or quality of non-Siemens products.
Read the detailed text in "Manufacturer recommendations" in the appendix.
5.4.6.4
Cooling connection adapter
Mounting the cooler connection adapter for motors with integrated cooling
The components required for connecting the cooler for motors with integrated cooling can
usually be mounted with standard tools. The cooling connection adapter is not mounted for
motors which are not equipped with a precision cooler.
For mounting the cooling connection adapter, you require 3 cylinder head screws. The
cooling ducts are sealed by means of O-rings as shown in the following diagram. The
cylinderhead screws and O-rings are supplied with the cooling connection adapter.