Start-Stop Push Button

A1

49SAP05

For-Rev-Stop Push Button

A2

49SAP02

High-Low-Stop

A2

49SAP03

H-O-A Selector Switch

A3

49SAS01

OFF/ON Selector Switch

A4

49SAS04

For-O

ff-

Rev Selector Switch

A5

49SAS02

High-O

ff-

Low Selector Switch                   A5

49SAS03

Keyed H-O-A Selector Switch

A9

49SAS09

Pilot Light Kit  Voltages:

E-600V, F-120V, G-240V,

H-480V, J-24V
Pilot Light Red  “ON”

FA

49SPL0BR(E,F,G,H,J)

49SPL0BG(E,F,G,H,J)

49SPL0CG(E,F,G,H,J)

49SPL0CR(E,F,G,H,J)

49SPL0AG(E,F,G,H,J)

49SPLPBG(E,F,G,H,J)

49SPL0AR(E,F,G,H,J)

49SPLPBR(E,F,G,H,J)

Pilot Light Green  “ON”

FB

Pilot Light Red  “Run”

FC

Pilot Light Green  “Run”

FD

Pilot Light Red  “

Off

F J

Pilot Light Green  “

Off

” 

              FK

Push-to-Test Red  “ON”

FS

Push-to-Test Green  “ON”

FT

Push-to-Test Green  “

Off

Pilot Light White  “Control Power On”

OL Relay Trip Alarm Light - Amber

FL

Control Power Transformers

Standard Capacity:

Sizes 0 - 2.5

Sizes 3 - 3.5

Size 4

208/120V

KTH050

KTH100

KTH150

208/24V

KTG050

KTG100

KTG150

240/120V

KT8050

KT8100

KT8150

277/120V

KT7050

KT7100

KT7150

277/24V

KT5050

KT5100

KT5150

480/120V

KT8050

KT8100

KT8150

480/24V

KT4050

KT4100

KT4150

600/120V

KT9050

KT9100

KT9150

600/24V

KT6050

KT6100

KT6150

KT_ _ 50 is 45VA  (primary fusing not required)
KT_ _ 100 is 100VA (with primary fusing)
KT_ _ 150 is 150VA (with primary fusing)

E.  Motor Starter or Contactor

See device label for appropriate replacement parts sheet.

F.  Auxiliary Contacts - Not Shown

Auxiliary

Contacts

(Installed on

contactor)
1NO

G10

1-49AB10

2NO

G20

1-49AB20

3NO

G30

1- 1-49AB10

4NO

G40

1-49AB40

1NC

G01

1-49AB01

2NC

G02

2-49AB01

1NO & 1NC

G11

1-49AB11

1NO & 2NC

G12

1-49AB12

2NO & 1NC

G21

1-49AB21

2NO & 2NC

G22

1-49AB22

2NO & 1NC

G31

1-49AB31

Disconnect  switch interlock 2NO/2NC

30 - 200A

GY

HA261234

Ground Lug 3-Conductor

L10

75D28182001

120V Coil  Transient Suppressor - Per Coil   SS 

  49D26344

Relay 2NO & 2NC (120V)

R22

3RH2122-1AK60

Relay 4NO (120V)

R40

3RH2140-1AK60

Relay 4NC (120V)

R04

3RH2122-1AK60

Factory

Suffix

Field

Kit

G.  Control Options - Not Shown

Factory

Suffix

Field

Kit

Control Options

Factory

Suffix

Field

Kit

Control Relays

D.  Control Power Transformers

Pilot Lights

Factory

Suffix

Field

Kit

Factory

Suffix

Field

Kit

Push Buttons/

Selector Switches

C.  Pilot Devices

Replacement Parts

49SPLPAG(E,F,G,H,J)

49SPL0DW(E,F,G,H,J)

49SPL0EA(E,F,G,H,J)

FU

FW

Replacement Parts and Instruction Guide

E87010-A0137-T003-A4

Siemens Industry, Inc. 3617 Parkway Ln, Peachtree Corners, GA 30092   www.usa.siemens.com

         3          A5E31166526A-003    

H. Quarter-Turn Latch

Enclosure Type                            Catalog Number

1, 3R, 12                                        75D46260004

4, 4X                                               75D46260005

J. Overload Relay Reset Operator

Enclosure Type                            Catalog Number

1                                                      49MBRS1

3R, 4, 4X, 12  

 

  49MBRS2

    

Summary of Contents for 17

Page 1: ...sult if proper precautions are not taken Warning Indicates death severe personal injury or property damage can result if proper precautions are not taken Caution Indicates personal injury or property damage may result if proper precautions are not taken Short Circuit Explosion Hazard Can cause death serious personal injury or property damage Fully engage all door latches and spread ends of door hi...

Page 2: ...itch Type Selection Disconnect Fuse Clip Ampere Rating 3 ED63A003 10 ED63A010 25 ED63A025 30 ED63A030 50 ED63A050 100 ED63A100 125 ED63A125 150 FXD63A150L B1 Disconnect Switch Handle and Mechanism Class 17 25 32 Enclosure Type 1 3R 4 4X 12 Disconnect Size Amps Enclosure Size Handle Assembly Only Handle Assembly Disc Mech 3 125 100 125 150 250 24 H x 11 W x 8 D 24 H x 20 W x 8 D 36 H x 24 W x 8 D A...

Page 3: ...th primary fusing KT_ _ 150 is 150VA with primary fusing E Motor Starter or Contactor See device label for appropriate replacement parts sheet F Auxiliary Contacts Not Shown Auxiliary Contacts Installed on contactor 1NO G10 1 49AB10 2NO G20 1 49AB20 3NO G30 1 49AB20 1 49AB10 4NO G40 1 49AB40 1NC G01 1 49AB01 2NC G02 2 49AB01 1NO 1NC G11 1 49AB11 1NO 2NC G12 1 49AB12 2NO 1NC G21 1 49AB21 2NO 2NC G2...

Page 4: ...link to the mechanism The retaining ring should not spin freely on the shaft after it is installed 8 No handle adjustment is required 9 Verify that the handle mechanism turns ON and OFF the circuit breaker 10 Verify that the door cannot be opened with the handle in the ON position 1 Remove the 2 screws from the connecting link 2 Use a 5 16 wrench to remove the two 1 4 20 screws and lock washers wh...

Page 5: ...en provided to mount a new circuit breaker if necessary 5 Install the new handle assembly onto the enclosure 6 Reinstall the two 1 4 20 screws and lock washers Make sure the handle housing is sealed against the enclosure flange as this prevents the entry of moisture 7 Reinstall the two screws that connect the handle link to the pivot assembly 8 No handle adjustment is required 9 Verify that the ha...

Page 6: ...ed to access the mounting screws 4 Hardware has been provided to mount a new circuit breaker if necessary 5 Install the new handle assembly onto the enclosure 6 Reinstall the two1 4 20 screws and lock washers Make sure the handle housing is sealed against the enclosure flange as this prevents the entry of moisture 7 Reinstall the two screws that connect the handle link to the pivot assembly 9 Veri...