SIELCO srl
- Via Toscana, 57/59 - 20090 BUCCINASCO (Mi) - ITALY - tel. 02 - 45713300 - www.sielco.org
RTX19/1 - USER & MAINTENANCE MANUAL - rev.1.4 - 02/17
Page 7
FUSE T 2A L 250V
POWER
10/100T
MONITOR
110-240V
~
50-60Hz 40VA
50 OHM
RF INPUT
1 Ground
2
3 Signal -
STEREO
RIGHT
LEFT
MONO
RS232
REMOTE
MPX+
MPX-
10-75000 Hz
N+1 CONTROL
M
A
D
E
IN
IT
A
L
Y
9
10 11
14
15
16
13
17
18
19 20
21
22
12
REAR VIEW
All the Receiver I/O connectors but the IF monitor output are on the rear panel:
9
Mains power supply switch
10 IEC320 mains socket
11 Fuse holder with internal reserve fuse
12 Additional earth screw
13 RF antenna, N-type connector
14 10/100T LAN port
15 "N+1" parallel optional control port, on a Dsub9 female type connector
16 Stereo decoded output (optional), on XLR balanced male connectors
17 Monophonic filtered output, on XLR balanced male connector
18 LF Monitor output, on BNC-type connector. May be internally connected as an additional MPX
composite or wide-band or mono signal output.
19 Main MPX output reversed in phase, on BNC-type connector
20 Main MPX output, on BNC-type connector
21 Parallel Remote Control port, on a Dsub9 male type connector
22 Serial RS232 Remote Control port, on a Dsub9 female type connector