Caution
Do not operate the heating clamp upside down.
Potential problem:
The trapped heat may damage the heating clamp housing.
Action:
If the housing gets extremely hot, shut off the device and let it cool down.
– Prepare device and workstation.
– Connect the heating clamp to the power supply.
– Start the device.
after it is switched on, the device is in start mode. The heating plates are automatically heated to the most
recently set “cooling temperature”.
– adjust the heating clamp settings in calibration mode if necessary.
– Set and save the splicing parameters in setting mode.
· Heating temperature
· Holding time
· Cooling temperature
– Insert the prepared splice guide into the heating clamp.
– Start heating cycle.
Heating plates are heated to the previously set heating temperature.
· Once the heating temperature has been reached, the holding time starts automatically.
· Once the holding time is complete, the cooling process starts automatically.
– When the preset cooling temperature has been reached, remove the splice guide and the finished splice.
– Insert other splice guides into the heating clamp to continue splicing or switch off the heating clamp.
Note
If approx. 2 minutes pass without any button being pressed, the device switches off.
3.4 Basic belt splicing procedure