Installation and operating instructions
AEROTUBE
10.2016
5
Installation
• Remove the AEROTUBE carefully from the packaging and do not place it on the filter casing or the outer cover. We
recommend storing the unit on a soft surface (e.g. cardboard or sheet) during installation.
• Check AEROTUBE for cleanliness prior to installation. If necessary, thoroughly clean the unit as described.
• Install the AEROTUBE in its intended installation position and seal it in accordance with the installation directives applicable on site.
• Close the valve via the slide switch on the filter casing to prevent contamination (e.g. dust) from entering the unit during
installation.
Drill a core hole (in the room side) and shorten the sound absorption pipe
1.
0°― 0.5°
AEROTUBE DD 110: ≥ Ø 120
AEROTUBE DD 150: ≥ Ø 150
2.
Trim the pipe according to the formula:
Note:
With composite thermal insulation systems
(WDVS), the flat duct for insulation is > 5 mm. Due to
this, the dimension
X
is extended accordingly.
Attention!
A pipe adapter is used additionally for
AEROTUBE DD 110 types FL, SFL, FUB and SFUB.
Hence the
X
dimension must be calculated as shown below:
X
X
30
Sound absorption pipe
Pipe adapter
WDVS
Summary of Contents for AEROTUBE DD 110