Installation and operating instructions
AEROTUBE
10.2016
17
Technical specifications
AEROTUBE, Type Standard
Material description
AEROTUBE DD 110
AEROTUBE DD 150
Sound absorption D
n,e,w
L = 500 mm 50 dB
L = 400 mm 48 dB
L = 500 mm 46 dB
Volumetric flow
11 m³/h at 2 Pa
16 m³/h at 4 Pa
24 m³/h at 8 Pa
26 m³/h at 10 Pa
14 m³/h at 2 Pa
20 m³/h at 4 Pa
29 m³/h at 8 Pa
32 m³/h at 10 Pa
AEROTUBE, types with vent duct UFD (enhanced sound absorption)
Material description
AEROTUBE DD 110
AEROTUBE DD 150
Sound absorption* D
n,e,w
L = 500 mm 68 dB
L = 340 mm 64 dB
L = 240 mm 61 dB
L = 500 mm 65 dB
L = 340 mm 61 dB
*Information according to device types FL
Accessories
Material description
Material no.
Note
Adapter for vent duct UF/UFD
1663301-001
Vent duct UFD
159689-001
Sound insulation element (SK)
L5473800-096010
2 to 4 sound insulation elements can be
positioned in the sound absorption pipe
to optimise the sound absorption values.
(only available for AEROTUBE DD 150)