Siegenia AEROMAT VT WRG 1100 Operating Instructions Manual Download Page 4

4

AEROMAT VT WRG 1100 

Original operating instructions

10.2018

1. Target group of this documentation

•  This documentation is intended for use by specialists and end users.
•  All instructions concerning assembly, installation and repairs described in this document are to be performed exclusively 

by experienced professionals with training and practice in the installation, commissioning, servicing and maintenance of 
decentralised ventilation units.

•  All instructions on operation, care and maintenance as well as the rectification of malfunctions described here are 

intended for specialists end users.

•  After the successful assembly and installation, the installation company is committed to handing over the operating 

instructions to the end user.

2. Intended use

•  The AEROMAT VT WRG 1100 is intended for installation in the exterior windows/walls of permanent structures in 

accordance with our installation and design documents and the specifications of our operating instructions and is only 
suitable for the ventilation of enclosed rooms.

•  The AEROMAT VT WRG 1100 must be installed in the intended installation position (horizontal or vertical). The intended 

installation position results from the weather grille preassembled in the factory. 

Weather grille: 

911 HW

Installation position:

 

Horizontal

Weather grille:

 911 HW-g 

(concealed installation in the 
wall)

Installation position:

 

Horizontal

Weather grille: 

911 CW

Installation position:

 

Horizontal

•  Do not use the AEROMAT VT WRG 1100 in environments with corrosive or explosive atmospheres (dust, vapour or gas).
•  Do not install the unit in contaminated rooms and ensure that no hazardous substances can be drawn in.
•  The AEROMAT VT WRG 1100 may be installed in damp locations in protection class 2; however, the socket used must 

be in at least protection class 3.

•  If the AEROMAT VT WRG 1100 is to be used in a room with a heating unit that draws air from the room, prior 

authorisation must be obtained from the proper authorities, such as the officially appointed district chimney sweep. 
Intended use requires that any combustion air lines and exhaust gas systems of solid fuel heating units must be able to be 
shut off.

•  Only operate and/or store the AEROMAT VT WRG 1100 at temperatures between ‒ 15 °C and +40 °C.
•  Use the AEROMAT VT WRG 1100 only with genuine accessories from SIEGENIA.
•  Comply with the safety regulations for operating electrical equipment and, if necessary, for ladders, steps and work 

overhead or at certain heights.

•  Use the AEROMAT VT WRG 1100 only when it is in a technically sound condition.
•  Do not modify the unit's components in any way.
•  Ensure that the device's ventilation openings are kept free and are not blocked by other equipment, furniture or objects.

Summary of Contents for AEROMAT VT WRG 1100

Page 1: ...AERO Sound absorbing ventilator with heat recovery AEROMAT VT WRG 1100 Window systems Door systems Comfort systems ORIGINAL OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...Scope of delivery equipment 6 6 Installation 7 7 Mains supply 10 8 Unit function 12 9 Membrane key and LED display 13 10 Commissioning 14 11 Operation 14 12 Care and maintenance 18 13 Rectification o...

Page 4: ...HW Installation position Horizontal Weather grille 911 HW g concealed installation in the wall Installation position Horizontal Weather grille 911 CW Installation position Horizontal Do not use the AE...

Page 5: ...shock or fire To prevent personal injury or damage to property always comply with the following instructions Work on a 230 V AC mains power supply may only be performed by a qualified electrician If...

Page 6: ...2 Translation of the original operating instructions 3 SIEGENIA Comfort app quick start instructions Function Heat recovery Automatic mode Air quality sensor and or Temperature and humidity sensor Op...

Page 7: ...w lintel Concealed installation in the window lintel 6 2 Additional requirements for AEROMAT VT WRG 1100 smart The AEROMAT VT WRG 1100 smart should be installed to be as free from interference as poss...

Page 8: ...s therefore necessary to adhere the AEROMAT VT WRG 1100 at points where rain could permeate Example Concealed installation in the wall with wall duct Example Concealed installation in the lintel AEROM...

Page 9: ...nium mounting angles AEROMAT VT WRG 1100 with 911 CW weather grille AEROMAT VT WRG 1100 with 911 HW weather grille Dimension Meaning a Mounting area for bracket b Screw and drilling area e g for wall...

Page 10: ...n class 3 Insert the Euro plug into a suitable 230 V AC mains power supply 7 2 External switch connection Exposed electrical components Risk of fatal injury from electric shock or fire Work on a 230 V...

Page 11: ...tic Colour Value Black Blower level 1 Grey Blower level 2 White Blower level 3 power level Red Automatic Brown L1 Blue N only with AEROMAT VT WRG 1100 Var 2 and Var 4 with sensors 7 4 Wiring diagram A...

Page 12: ...h air from the outside to flow into the room pressure differential ventilation Because the fans are not moving the air in both air canals flows in the same direction meaning that air is generally draw...

Page 13: ...mode blower level 2 1 The power level can only be controlled manually and is not available in automatic mode 2 In automatic mode the fans are not switched off but continue to run at a minimum level 9...

Page 14: ...e calibration The calibration is completed after approx 20 min Requirements for a faultless calibration The room must be well aired before the calibration The room temperature must be between 5 C and...

Page 15: ...Var 2 and Var 4 Following a power failure the AEROMAT VT WRG 1100 switches to the last level to be used automatic sensor calibration is performed first in units with sensors see page 14 Switching sequ...

Page 16: ...sed sensor calibration is performed first in units with sensors see page 14 AEROMAT VT WRG 1100 Var 1 and Var 3 without sensors Recommendation use a 3 stage rotary switch provided onsite 0 1 2 3 0 1 2...

Page 17: ...p Blower performance The blower performance can be set manually On application of the automatic mode the manually adjusted blower performance is overridden Automatic mode For information on the automa...

Page 18: ...use cleaning agents that are aggressive or contain solvents or sharp edged objects as these may damage the surfaces of the casing Never clean the unit with a high pressure cleaner or steam jet cleaner...

Page 19: ...e below shows the opening direction for a AEROMAT VT WRG 1100 that has been installed horizontally 1 Open the locking bolts on the right and left 2 Pull out the front panel 3 Slide the membrane key ou...

Page 20: ...t panel see also page 19 2 Remove the retaining spring 3 Remove the exhaust air filter and dispose of it as household waste 4 Insert a new exhaust air filter 5 Reassemble the AEROMAT VT WRG 1100 in th...

Page 21: ...e 90 4 Remove the cover 5 Remove the insulation 6 Remove the filter compartment cover 7 Remove the foam padded wedge 8 Remove the outside air filter and dispose of it as household waste 9 Remove the i...

Page 22: ...ge 19 2 Remove the exhaust air filter see also page 20 3 Turn the supporting piece 90 4 Remove the cover 5 Remove the foam padding 6 Remove the heat exchanger and clean it thoroughly under running wat...

Page 23: ...router of the home network No WLAN connection to the smartphone tablet Restart smartphone tablet No WLAN connection to the AEROMAT VT WRG 1100 smart Reset AEROMAT VT WRG 1100 smart 1 Press membrane ke...

Page 24: ...56 m3 h Heat recovery efficiency3 max 62 Inherent noise4 at blower level 1 With blower level 2 With blower level 3 power level LpA approx 21 dB A LpA approx 27 dB A LpA approx 38 dB A Supply voltage...

Page 25: ...c input power 0 19 W m h 0 23 W m h n Control factor control typology 1 21 1 1 21 0 65 1 21 1 1 21 0 65 o Highest degree of inner and outer leakage rate inner outer leakage 9 8 p Mix rate inner area o...

Page 26: ...2012 A11 2014 EN 62233 2008 c 2014 53 EC RED Directive c1 Electromagnetic compatibility EN 301489 1 V 1 9 2 EN 301 489 17 V 2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 c2 Electrical safety Establishment...

Page 27: ......

Page 28: ...85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4...

Reviews: