AEROMAT VT WRG 1100
Original operating instructions
10.2018
10. Commissioning
10.1 Automatic calibration of the air quality sensor (AEROMAT VT WRG 1100 Var. 2 and Var. 4)
• The sensors are calibrated automatically as soon as the AEROMAT VT WRG 1100 is connected to the power supply
(and also following a power failure).
• 2 LEDs flash red and the membrane key flashes blue during the calibration.
• The calibration is completed after approx. 20 min.
Requirements for a faultless calibration
• The room must be well aired before the calibration.
• The room temperature must be between 5 °C and 40 °C.
• There should be no persons or animals in the room.
• The membrane key must not be activated during the process.
11. Operation
11.1 Ventilation without fans
1. Open both sliders
2. Set the blower level to 0
11.2 Ventilation with fans
1. Open both sliders
2. Set the required blower level using either the membrane key or the external switch
2.
1.
External switch
Membrane key
(left)