![Siegenia AERO AEROMAT VT WRG 1000
smart Original Operating Instructions Download Page 22](http://html1.mh-extra.com/html/siegenia/aero-aeromat-vt-wrg-1000-smart/aero-aeromat-vt-wrg-1000-smart_original-operating-instructions_1265123022.webp)
03.2021
22/24
H47.FENS037EN-03
AERO
Original operating instructions
AEROMAT VT WRG 1000
16.3
Product data sheet
1254/2014
1254/2014
a
Producer
SIEGENIA
SIEGENIA
b
Model.identifier
AEROMAT VT WRG 1000
AEROMAT VT WRG 1000
smart
c
Energy.consumption.(SEV);
Energy.efficiency.class.(SEC.class)
(according.to.climatic.zone.warm./.average./.cold)
−11.2 kWh/(m².·.a);.E
−32.0 kWh/(m².·.a);.B
−68.2 kWh/(m².·.a);.A+
−11.7 kWh/(m².·.a);.E
−32.5 kWh/(m².·.a);.B
−68.6 kWh/(m².·.a);.A+
d
Type
WLA./.ZLA
WLA./.ZLA
e
Type.of.drive
Multi-stage.drive
Rotational.speed.control
f
Heat.recovery.system
Recuperative
Recuperative
g
Thermal.efficiency
51.3.%
51.3.%
h Maximum.flow.rate
52.m³/h
52.m³/h
i
Electrical.input.power
24 W
26 W
j Noise level
44.dB.(A)
44.dB.(A)
k Relative.air.flow.rate
38.m³/h
38.m³/h
l
Relative.pressure.differential
―
―
m
Specific.input.power
0.3.W/(m³/h)
0.34.W/(m³/h)
n
Control.factor./.control.typology
0.65 / 1.21
0.65 / 1.21
o
Highest.degree.of.inner.and.outer.leakage.rate
(inner./.outer.leakage)
3.6.%./.5.8.%
3.6.%./.5.8.%
p Mix.rate.(inner.area./.outer.area)
9.%./.‒1.%
9.%./.‒1.%
q Instructions.for.replacing.filter
see.page.
see.page.
r
Instructions.for.the.mounting.of.outside.air./.
exhaust.air.grilles
(for.one-directional.ventilation.units)
―
―
s
Instructions.for.dismantling
―
―
t
Pressure.fluctuation.sensitivity.of.the.air.flow
(at.+20.Pa.and.–20.Pa)
10.%./.10.%
10.%./.10.%
u
Air.tightness.between.inside.and.outside
2.6.m³/h
2.6.m³/h
v
Annual.power.consumption
2.6.kWh/a
2.4.kWh/a
w
Annual.saving.of.heating.energy
(according.to.climatic.zone.warm./.average./.cold)
17.1.kWh/a
37.8.kWh/a
74.kWh/a
17.1.kWh/a
37.8.kWh/a
74.kWh/a