![Siegenia AERO AEROMAT VT WRG 1000
smart Original Operating Instructions Download Page 11](http://html1.mh-extra.com/html/siegenia/aero-aeromat-vt-wrg-1000-smart/aero-aeromat-vt-wrg-1000-smart_original-operating-instructions_1265123011.webp)
H47.FENS037EN-03
03.2021
11/24
Original operating instructions
AEROMAT VT WRG 1000
AERO
9
Unit function
9.1
Ventilation without blowers
•
The.room.is.ventilated.through.air.pressure.
compensation.between.the.indoor.and.outdoor.
air.(pressure.differential)..As.this.happens,.the.air.
normally.flows.into.the.room.from.outside.
•
The.air.flow.into.the.room.varies.as.the.wind.
pressure.changes.with.the.weather.
9.2
Ventilation with blowers
•
The.outside.air.(2).is.drawn.in.and.enters.the.room.
as.filtered.supply.air.(10).
•
The.exhaust.air.(11).is.drawn.in.and.is.released.into.
the.atmosphere.as.exhaust.air.(1).
•
Both.air.flows.drawn.through.the.heat.exchanger.
(4)..Here,.particularly.during.cold.times.of.the.year,.
the.outside.air.is.pre-heated.by.the.warm.exhaust.
air.before.it.enters.the.room.as.supply.air.
3
7
11
5
9
2
4
8
1
6
10
Item
value
1
Exhaust.air
2
Outside air
3
Exhaust.air.fan
4
Heat.exchanger
5
Supply.air.sensor:.humidity/temperature
6
Supply.air.fan
7
Supply.air.filter
8
Exhaust.air.sensor.(optional)
9
Exhaust.air.filter
10
Supply.air
11
Exhaust.air
Summary of Contents for AERO AEROMAT VT WRG 1000 smart