Code
Error message
Error reaction
Possible reason
8
Node Guarding
3
8
Communication node monitoring:
monitoring time expired (configu‐
rable)
9
EEPROM error
4
9
Error in EtherCAT EEPROM
10 Heartbeat / Watchdog
2, 3, 4
10 Heartbeat monitoring: monitoring
time expired (configurable)
E12
(0x10C)
(268
d)
Mains 'Ready for operation' is
missing
Motor is stopped by parameter-
driven ramp and drive is disabled
(controlled standstill).
▶
Power output stage was switched
on, when mains supply was discon‐
nected/interrupted.
E15
(0x10F)
(271
d)
Endat / Hiperface communication
faulty
Motor is stopped by quick stop
ramp and drive is disabled
(controlled standstill).
▶
Communication of EnDat/Hiperface
is faulty.
E17
(0x311)
(785
d)
FPGA power output stage shut‐
down
Motor is stopped immediately.
▶
Overload in power supply unit
E17
(0x311)
(785
d)
Zero voltage control DC link (only
SD2M)
Motor is stopped immediately.
Mains thyristors are no longer
controlled.
▶
Window range of the zero voltage
control has been exceeded.
▶
Unbalanced load
Please contact SIEB & MEYER.
E18
(0x312)
(786
d)
Error in spindle selection
Motor is stopped immediately.
▶
Spindle selection was not valid at
“Switch on”.
E25
(0x319)
(793
d)
Power supply load too high
Drive is stopped by limitation of
motor torque.
▶
Output power of drive is greater
than rated power of power supply
unit, since the dimensioning of
drive and motor are not compatible.
E26
(0x31A)
(794
d)
Motor temperature too high
Motor is stopped by error ramp
and current limitation.
▶
Wrong parameters entered for the
motor or wrong dimensioning of the
motor
E27
(0x31B)
(795
d)
Ambient temperature too high
Motor is stopped by error ramp
and current limitation.
▶
Insufficient device cooling
E28
(0x31C)
(796
d)
Power output stage temperature
too high
Motor is stopped by error ramp
and current limitation.
▶
Insufficient cooling of power output
stage (heat sink)
E29
(0x31D)
(797
d)
Motor load too high (Motor I²t)
Motor is stopped by error ramp
and current limitation.
(1)
▶
Average motor load is too high due
to mechanical problems
▶
Wrong dimensioning of the motor
E30
(0x31E)
(798
d)
Power output stage load too high
(I²t)
Motor is stopped by error ramp
and current limitation.
(1)
▶
Average load of output stage is too
high due to mechanical problems
▶
Wrong dimensioning of the drive
E31
(0x31F)
(799
d)
Speed error or slip too high
SERVO / VECTOR: Drive is
limited by current monitoring via
short-circuit of the motor phases.
(1)
HSPWM: Drive is stopped by error
ramp and current limitation.
▶
Motor is not able to comply with the
set speed (e.g. defective motor,
mechanical problems, wrong para‐
meters), failure of the measuring
system
E33
(0x521)
(1313
d)
Power supply load monitoring ->
mains voltage too high
Power supply unit will be discon‐
nected from mains.
▶
Parameterized mains voltage does
not match the connected voltage
▶
Device connection is incorrect.
▶
Heavy fluctuation of the power
supply towards overvoltage
Status Display and Error Messages
W
84
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy
10
Summary of Contents for SD2S 0362249xy
Page 4: ...Chapter Overview W 4 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 8: ...Content W 8 Drive System SD2S Hardware Description 0362X49xy 0362129xy...
Page 12: ...About this Manual W 12 Drive System SD2S Hardware Description 0362X49xy 0362129xy 1...
Page 16: ...General Information W 16 Drive System SD2S Hardware Description 0362X49xy 0362129xy 2...
Page 30: ...Drive Amplifier SD2S W 30 Drive System SD2S Hardware Description 0362X49xy 0362129xy 5...
Page 54: ...Connector Pin Assignment W 54 Drive System SD2S Hardware Description 0362X49xy 0362129xy 7...
Page 80: ...Setup W 80 Drive System SD2S Hardware Description 0362X49xy 0362129xy 9...