5.5
Technical Data
Note
In order to comply with the EMC Directive 2014/30/EU the device must be operated with
an external line filter. A list of suitable line filters is provided in the appendix (see
D.3 “Line Filters by TDK & EPCOS Group”, page 117
Device variant 03622xxxx
80AF
81BF
82AF
83BF
Output stage (switching frequency = 8 kHz)
Output power for RMS phase current
[kVA]
120
(1)
240
(1)
145
(2)
345
(2)
Peak amplitude
[A
p
]
300
600
300
707
Peak amplitude
at 0 Hz
[A
p
]
150
300
150
353.5
RMS value
[A
rms
]
212
424
212
500
Continuous phase cur-
rent
(3)
(±3 %)
RMS value at
0 Hz
[A
rms
]
106
212
106
250
Peak amplitude
[A
p
]
375
750
375
750
Peak amplitude
at 0 Hz
[A
p
]
187.5
375
187.5
375
RMS value
[A
rms
]
265
530
265
530
Peak phase current
(3)
(±3 %)
RMS value at
0 Hz
[A
rms
]
132.5
265
132.5
265
Max. time for peak current
[s]
60
60
60
60
Derating frequency
[Hz]
30
30
30
30
Max. output frequency
[Hz]
1000
1000
1000
1000
Output frequency stability
[%]
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
Output stage (switching frequency = 16 kHz)
Output power for RMS phase current
[kVA]
120
(1)
240
(1)
145
(2)
293
(2)
Peak amplitude
[A
p
]
300
600
300
600
Peak amplitude
at 0 Hz
[A
p
]
150
300
150
300
RMS value
[A
rms
]
212
424
212
424
Continuous phase cur-
rent
(3)
(±3 %)
RMS value at
0 Hz
[A
rms
]
106
212
106
212
Peak amplitude
[A
p
]
375
750
375
750
Peak amplitude
at 0 Hz
[A
p
]
187.5
375
187.5
375
RMS value
[A
rms
]
265
530
265
530
Peak phase current
(3)
(±3 %)
RMS value at
0 Hz
[A
rms
]
132.5
265
132.5
265
Max. time for peak current
[s]
60
60
60
60
Derating frequency
[Hz]
30
30
30
30
Max. output frequency
[Hz]
2000
2000
2000
2000
Output frequency stability
[%]
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
Mains supply
Number of phases
3
3
–
–
Minimum
[V
AC
]
200
400
–
–
AC voltage (±10 %)
Maximum
[V
AC
]
480
480
–
–
Minimum
[Hz]
50
50
–
–
Frequency (±2 Hz)
Maximum
[Hz]
60
60
–
–
Mains phase current at rated power and
mains voltage of 400 V
rms
[A
rms
]
180
360
–
–
Short circuit current rating (SCCR)
[kA]
10
18
–
–
External power supply
Current at rated power and 600 V
[A
rms
]
–
–
260
(4)
600
(4)
25
Drive System SD2M - Hardware Description 036228xxF
Drive Amplifier SD2M