Code
Description
W15
Ballast resistor load greater than parameterized warning threshold W15 (ballast resistor I²t)
W16
Safety circuit is active
W17
Unknown commutation angle
W18
Hiperface / EnDat OEM data not valid
W19
Dirt signal encoder input 0
W20
Dirt signal encoder input 1
W21
Dirt signal encoder input 2
W22
Power supply unit load greater than 90% of the rated power
W23
Reserved
W24
Current or current rise greater than warning threshold W24 (warning current)
W25
Reference speed less than minimum motor speed
W26
Current greater than warning threshold W26 (warning overload current)
W27
Reserved
W28
Reserved
W29
Reserved
W30
Reserved
W31
Reserved
9.2.4
Messages of the Quick Stop Functions
Code
Description
H01
Digital input "Switch on" waits for positive edge to switch the drive on (This function is only
active when the input is set as "Switch on type 2 (with positive edge)".)
H03
Software function "Quick stop"
H04
Digital input "Quick stop"
H07
Software positioning error "Negative limit"
H08
Software positioning error "Positive limit"
H09
Bus system "Quick stop" (The quick stop bit is set to 0)
H11
Digital input "Negative limit switch"
H12
Digital input "Positive limit switch"
H13
Digital input "Speed Enable"
H14
Magnetic bearing calibration active
93
Drive System SD2M - Hardware Description 036228xxF
Status Display and Error Messages