background image

Sidus F1Q – free flight electronic timer 

4/9 

Programming the Timer  

 
The Programmer is needed to modify the timing sequence and dethermalize the model. It 
also allows to calibrate the servo positioning and set other functions. 
 
Each time the Programmer is started, it briefly displays the following startup screen 
 
 
 
 
  
 
then it switches to the MAIN menu 
 
 
 
 
 
 
 
The possible options are displayed at the corners of the rectangle window of the display: 
an  option  is  chosen  by  pressing  the  button  located  at  the  same  corner  as  the  rectangle 
made up of the buttons named T1, T2, T3, T4 (see drawing). 
 

A long (press and hold) or short (press and release) key pressure may be required 
according  to  the  following  rule:  choices  displayed  in  upper  case  (e.g.  READ
UNLOCK,..)  require  a  long  pressure  (press  and  hold),  choices  displayed  in  lower 

case  except  the  first  character  (e.g.  Exit,  Servo,..)  require  a  short  pressure  (press  and 
release). 

 

To allow the Programmer to communicate with the Timer, make sure the Timer is 
ON and aim the Timer  at the Programmer closer than 20 cm. with the IR sensors 
mutually  visible.  In  case  of  communication  failure,  the  message 

ERROR!

ERROR!

ERROR!

ERROR!

”  is 

displayed on the Programmer  

Timing visualization 

 

For  each  function  the  Programmer  displays  the  programmed  activation  time  and  the 
current time memory: 
 
 
 
 
 
Motor stop time (MOTOR) and DT time are displayed  
explicitly 
 
All the displayed values are absolute, i.e. referred to time zero. 

READ

READ

READ

READ         R

         R

         R

         RDT

DT

DT

DT 

  

 

UNLOCK

UNLOCK

UNLOCK

UNLOCK       

       

       

       SET

SET

SET

SET 

  

 

 

FUNC4    t=16.8s

FUNC4    t=16.8s

FUNC4    t=16.8s

FUNC4    t=16.8s 

  

 

Exit

Exit

Exit

Exit     tm1

     tm1

     tm1

     tm1 

  

 

 

function nr. 

e.g. FUNC4 is activated 16.8s after start 

MOTOR    t=

MOTOR    t=

MOTOR    t=

MOTOR    t=14.9s

14.9s

14.9s

14.9s 

  

 

Exit

Exit

Exit

Exit     tm1

     tm1

     tm1

     tm1 

  

 

 

DT        t=180s

DT        t=180s

DT        t=180s

DT        t=180s 

  

 

Exit

Exit

Exit

Exit      tm1

      tm1

      tm1

      tm1 

  

 

 

current timing memory nr. 

activation time 

MAIN MENU 

TIMING MENU 

SIDUS Timer

SIDUS Timer

SIDUS Timer

SIDUS Timer F1Q

 F1Q

 F1Q

 F1Q 

  

 

V

VV

V5

55

5.20 B059 12/09      

.20 B059 12/09      

.20 B059 12/09      

.20 B059 12/09      

 

sw vers.  RDT code 

date 

startup screen 

Summary of Contents for F1Q

Page 1: ...Sidus F1 Sidus F1 Sidus F1 Sidus F1Q Q Q Q Quick Guide Revision 1 3 October 2010 M U 2009 2010...

Page 2: ...as on board buzzer a led lamp built in radio DT and Radio motor cut off Getting Started Refer to the pictures below to locate the system components Locate the connectors the IR sensor the red LED the...

Page 3: ...eps 3 times then the motor is started After about 3 sec the LED starts flashing fast and the buzzer beeps constantly From this moment the model can be thrown the timing sequence will start as soon as...

Page 4: ...nicate with the Timer make sure the Timer is ON and aim the Timer at the Programmer closer than 20 cm with the IR sensors mutually visible In case of communication failure the message ERROR ERROR ERRO...

Page 5: ...the screen for FUNC1 3 scroll the display with T3 T4 to view the screens related to the other functions motor stop time and DT Reach the function which activation time must be modified 4 press and hol...

Page 6: ...To abort the modifications without updating the Timer just make the writing fail by aiming the Programmer away of the Timer then choose T4 Exit Servo positioning modification This modification is nee...

Page 7: ...the model RDT The message RDT RMC Transmitting RDT RMC Transmitting RDT RMC Transmitting RDT RMC Transmitting will be displayed The effect of the command depends on the function that is currently in p...

Page 8: ...hese devices are visible from outside through a small transparent window Do not expose under direct sunlight Programmer and LiPo Battery The Programmer battery ensures about 200 DT activations and pow...

Page 9: ...for FUNC4 FUNC5 and FUNC6 so that once the 4th arm is released the disc remains in the same position whatever the activation time programmed for FUNC5 and FUNC6 until DT activation when the last step...