Sidus F1Q – free flight electronic timer 

3/9 

 
 
 

Timer 

Timing duration and resolution 

The  timing  sequence  (motor  stop  and  7  remaining  functions)  is  programmable.  The 
duration range of the motor and of the functions FUNC1 to FUNC6 is 0.1 a 99.9 sec. The 
duration range of DT function is 1 a 720 sec. (12 min). 
In  addition,  the  Timer  is  capable  to  store  up  to  5  separate timing sequences in as many 
timing memories (tm1,.., tm5).  

Using the Timer 

 
The  red  LED,  the  buzzer  and  the  disk  (or  servos)  position  indicate  the  current  Timer 
status. 
 

Every  time  the  battery  is  reconnected  to  the  ESC  the  Timer  gets  discharged  and 
brings the disc (or the servos) to the final position (DT position). 
 

Starting fro a discharged Timer the functions are: 
 
ARM  THE  TIMER
:  press  the  start  switch  to  bring  the  disc  (or  the  servos)  to  its  start 
position 
 
THROW THE MODEL: press and hold the start switch. The LED stays ON and the buzzer 
beeps  3  times,  then  the  motor  is  started.  After  about  3  sec.  the  LED  starts  flashing  fast 
and the buzzer beeps constantly. From this moment, the model can be thrown: the timing 
sequence will start as soon as the start switch is released. 
 

if the start switch is released  before the LED starts flashing , the motor is stopped 
and the and the Timer  remains armed and ready to start 
 

TERMINATE  THE TIMING SEQUENCE: while the timing sequence is in progress, it can 
be  terminated  (the  motor  stops  and  the  disc  or  the  servos  jump  to  DT  position)  buy 
pressing and holding the start switch 
 

Motor safety start lock: after completing a timing sequence, a new motor start is 
disabled  according  to  the  FAI  F1Q  class  rules,  and  to  avoid  an  inadvertent  motor 
start during retrieval. The motor start is re-enabled through the Programmer or by 

disconnecting and reconnecting the battery to the ESC. 
 

Automatic Timer sleep: the timer automatically “goes to sleep” if inactive for over 
about 2 min. The status of the Timer e and all the internal data are retained. The 
Timer is awakened by shortly pushing the start switch.  

Summary of Contents for F1Q

Page 1: ...Sidus F1 Sidus F1 Sidus F1 Sidus F1Q Q Q Q Quick Guide Revision 1 3 October 2010 M U 2009 2010...

Page 2: ...as on board buzzer a led lamp built in radio DT and Radio motor cut off Getting Started Refer to the pictures below to locate the system components Locate the connectors the IR sensor the red LED the...

Page 3: ...eps 3 times then the motor is started After about 3 sec the LED starts flashing fast and the buzzer beeps constantly From this moment the model can be thrown the timing sequence will start as soon as...

Page 4: ...nicate with the Timer make sure the Timer is ON and aim the Timer at the Programmer closer than 20 cm with the IR sensors mutually visible In case of communication failure the message ERROR ERROR ERRO...

Page 5: ...the screen for FUNC1 3 scroll the display with T3 T4 to view the screens related to the other functions motor stop time and DT Reach the function which activation time must be modified 4 press and hol...

Page 6: ...To abort the modifications without updating the Timer just make the writing fail by aiming the Programmer away of the Timer then choose T4 Exit Servo positioning modification This modification is nee...

Page 7: ...the model RDT The message RDT RMC Transmitting RDT RMC Transmitting RDT RMC Transmitting RDT RMC Transmitting will be displayed The effect of the command depends on the function that is currently in p...

Page 8: ...hese devices are visible from outside through a small transparent window Do not expose under direct sunlight Programmer and LiPo Battery The Programmer battery ensures about 200 DT activations and pow...

Page 9: ...for FUNC4 FUNC5 and FUNC6 so that once the 4th arm is released the disc remains in the same position whatever the activation time programmed for FUNC5 and FUNC6 until DT activation when the last step...

Reviews: