SR882 operation manual
~ 50 ~
higher than tank temperature.
Activate/deactivate the function:
►Press “Heating” button, temperature “60
℃
” blinks on the screen.
►Press “+”“-” button to adjust switch-on temperature, adjustable range 10
℃~
80
℃
, factory
set is 60
℃
.
After 20 seconds, this function is activated, signal
displays on the screen, and
heating signal blinks also. LED heating indication light is on.
►Press “Heating” button again, to switch-off manual heating function.
Note:
manual heating can only heat tank one time, after manual heating is triggered, when
temperature of tank rises up to the preset temperature, manual heating ceases, and manual
heating function will be deactivated automatically, if customer wants to heat again, you need
redo according to above steps.
5.3 Temperature check
Under standby status,
►Press “+”“-” button can check the value of temperature sensors T1~ T6, flow rate, pump
speed (
n%
), accumulative operation time of circuit pump (hp), daily thermal energy
(DKWH), accumulative thermal energy (KWH) or (MWH), Time and Date.
When checking temperature, T1
– T6 will display one by one, corresponding sensor
signal blinks. Press
“ESC” button, TST tank temperature can be displayed.
Note:
1. Value of accumulative operation time of circuit pump (hp), daily thermal energy (DKWH)
and accumulative thermal energy (KWH) or (MWH) can only be checked after triggering the
QHQM thermal energy measuring function.
2. Flow rate
(
L/M
)
can be displayed when digital flow counter is used in solar system. If
mechanical flow counter is used, th
en flow rate can’t display.