background image

                           

PHC-3 Alarm Descriptions

EN

MC_0117

Fault Code

Description

Cause

Action

10500.0.10

PHC Oil Level - Level Low

Hydraulic oil level is low

-Limit the use of thruster

-Inspect hydraulic oil level

-Check system for leaks and refi ll hydraulic oil

10500.0.13

PHC Oil Level - Open Circuit

Analog oil level sensor open circuit

-Sensor not connected or wire break.

-Verify sensor type in parameter 0201

-Disconnect sensor and measure that sensor resistance value is in 

range 0-180ohm.

10501.0.11

PHC Oil Temp - Level High

Oil temperature higher than 75°C (167°F)

-Limit the use of thruster to prevent temperature to rise.

-Check if the cooling pump is running and there is cooling water fl ow.

-Inspect seawater fi lter

-Verify that cooling pump is enabled in parameter 0301

10501.0.13

PHC Oil Temp - Open Circuit

Analog oil temp sensor open circuit

-Sensor not connected or wire break.

- Disconnect sensor and measure that sensor resistance value is in 

range 104ohm-147Kohm

-The wrong sensor is defi ned in parameter 0201

10501.0.16

PHC Oil Temp - Short Circuit

Analog oil temp input short circuit

-Input shorted to GND, check wiring/sensor

-Disconnect sensor and measure that sensor resistance value is in 

range 104ohm-147Kohm

10502.0.13

PHC Stablizier Pressure - Open Circuit

Stabilizer pressure sensor open circuit

-Sensor not connected or wire break.

-System incorrectly confi gured with stabilizer, parameter 1001  

-Replace sensor

10502.0.16

PHC Stablizier Pressure - Short Circuit

Stabilizer pressure sensor short circuit

-Wires shorted or sensor defective, check wiring/sensor

-Replace sensor

10502.0.19

PHC Stablizier Pressure - Under Limit

Stabilizer pressure has dropped below 20bar.

-Check accumulator charge pressure

-Check PTO pressure (if PTO powered)

-Check system for oil leaks

10502.0.20

PHC Stablizier Pressure - Over Limit

Stabilizer pressure is higher than:

set point + 30bar running from PTO

or set point + 15bar running from AC motor

-Check PTO pressure setting

-Check accumulator charge pressure

10502.0.26

PHC Stablizier Pressure - VALUE MAX

Stabilizer pressure reached sensor max value.

-Check that the correct sensor is fi tted

-Check that sensor range parameter 1010 match the sensor

-Check PTO pressure setting

10502.0.200 PHC Stablizier Pressure - Timeout

Stabilizer pressure has not reached 50% of setpoint parame-

ter 1003 after 30sec.

-Check the   pump feed shutoff  valve.

-Check PTO pressure (if PTO powered)

-Check system for oil leaks

10503.0.13

PHC System Pressure - Open Circuit

System pressure sensor open circuit

-Sensor not connected or wire break.

-Verify system pressure, parameter 0104

10503.0.16

PHC System Pressure - Short Circuit

System pressure sensor short circuit

-Wires shorted or sensor defective, check wiring/sensor

-Replace sensor

10504.0.13

PHC AI 1 - Open Circuit

Analog Input 1 (4-20mA) sensor open circuit

-Sensor not connected or wire break.

10504.0.16

PHC AI 1 - Short Circuit

Analog Input 1 (4-20mA) sensor short circuit

-Wires shorted or sensor defective, check wiring/sensor

-Replace sensor

10505.0.13

PHC AI 2 - Open Circuit

Analog Input 2 (4-20mA) sensor open circuit

-Sensor not connected or wire break.

10505.0.16

PHC AI 2 - Short Circuit

Analog Input 2 (4-20mA) sensor short circuit

-Wires shorted or sensor defective, check wiring/sensor

-Replace sensor

10508.0.13

PHC DOUT AC PUMP UNLOAD - Open Circuit

AC Pump Unload valve open circuit

-Check for open circuit, power consumption < 5.0 Watt

-System incorrectly confi gured with stabilizer, parameter 1001

10508.0.51

PHC DOUT AC PUMP UNLOAD - Current High

AC Pump Unload valve current higher than 4.0A

-Check wires and connections for short circuit

10509.0.13

PHC DOUT ACCUMULATOR DUMP - Open 

Circuit

Accumulator Dump valve open circuit

-Check for open circuit, power < 5.0 Watt

-System incorrectly confi gured with stabilizer, parameter 1001

10509.0.51

PHC DOUT ACCUMULATOR DUMP - Current 

High

Accumulator Dump valve current higher than 4.0A

-Check wires and connections for short circuit

10510.0.13

PHC DOUT STABILIZER - Open Circuit

Stabilizer valve open circuit

-Check for open circuit, power consumption  < 5.0 Watt

-System incorrectly confi gured with stabilizer, parameter 1001

10510.0.51

PHC DOUT STABILIZER - Current High

Stabilizer valve current higher than 4.0A

-Check wires and connections for short circuit

10511.0.13

PHC DOUT COOLING PUMP HYDRAULIC - 

Open Circuit

Hydraulic Cooling Pump valve open circuit

-Check for open circuit, power consumption  < 5.0 Watt

-Wrong cooling pump confi gured, parameter 0301

10511.0.51

PHC DOUT COOLING PUMP HYDRAULIC - 

Current High

Hydraulic Cooling Pump valve current higher than 4.0A

-Check wires and connections for short circuit

10512.0.13

PHC DOUT LS DUMP - Open Circuit

LS-Dump valve open circuit

-Check for open circuit, power consumption  < 5.0 Watt

-System wrong confi gured with thrusters, parameter 2001 or 2101

10512.0.51

PHC DOUT LS DUMP - Current High

LS-Dump valve current higher than 4.0A

-Check wires and connections for short circuit

10513.0.51

PHC DOUT PUMP #2 - Current High

Pump #2 valve current higher than 4.0A

-Check wires and connections for short circuit

10514.0.13

PHC DOUT 5 - Open Circuit

Digital Output 5 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption  < 5.0 Watt

-Output confi gured wrong, parameter 0505

10514.0.51

PHC DOUT 5 - Current High

Digital Output 5 current higher than 4.0A

-Check wires and connections for short circuit

10515.0.13

PHC DOUT 6 - Open Circuit

Digital Output 6 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption  < 5.0 Watt

-Output confi gured wrong, parameter 0506

10515.0.51

PHC DOUT 6 - Current High

Digital Output 6 current higher than 4.0A

-Check wires and connections for short circuit

10516.0.13

PHC DOUT 3 - Open Circuit

Digital Output 3 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption  < 5.0 Watt

-Output confi gured wrong, parameter 0503

10516.0.51

PHC DOUT 3 - Current High

Digital Output 3 current higher than 4.0A

-Check wires and connections for short circuit

PHC-3 Alarm Descriptions

EN

MC_0117

Fault Code

Description

Cause

Action

10517.0.13

PHC DOUT 2 - Open Circuit

Digital Output 2 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption < 5.0 Watt

-Output confi gured wrong, parameter 0502

10517.0.51

PHC DOUT 2 - Current High

Digital Output 2 current higher than 4.0A

-Check wires and connections for short circuit

10518.0.13

PHC DOUT 1 - Open Circuit

Digital Output 1 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption  < 5.0 Watt

-Output confi gured wrong, parameter 0501

10518.0.51

PHC DOUT 1 - Current High

Digital Output 1 current higher than 4.0A

-Check wires and connections for short circuit

10519.0.13

PHC DOUT 4 - Open Circuit

Digital Output 4 is confi gured as crossover and output is open 

circuit

-Check for open circuit, power consumption < 5.0 Watt

-Output confi gured wrong, parameter 0504

10519.0.51

PHC DOUT 4 - Current High

Digital Output 4 current higher than 4.0A

-Check wires and connections for short circuit

10520.0.51

PHC ECI PUMP POWER FEED - Current High

ECI cooling pump power current higher than 8.0A

-Check pump cable for damage and short circuits

-Make sure the connector on the cooling pump is correctly inserted.

-Replace cooling pump

10521.0.51

PHC Bow Thruster Power - Current High

Bow thruster PVG feed current higher than 3.0A

-Check PVG wires and connections for short circuit

10522.0.51

PHC Stern Thruster Power - Current High

Stern thruster PVG feed current higher than 3.0A

-Check PVG wires and connections for short circuit

10523.0.51

PHC Thruster Power - Current High

Bow or Stern PVG feed current higher than 3.3A

Check all bow and stern PVG signal wires for short circuits

10524.0.51

PHC ECI Cooling Pump - Current High

ECI cooling pump current higher than 13.0A

-Check ECI cooling pump cable for damage and short circuits

-Replace ECI cooling pump

10524.0.53

PHC ECI Cooling Pump - Overvoltage

ECI cooling pump overvoltage, voltage higher than 33.0V

-Check PHC-3 input voltage is below 33.0V

-Replace ECI cooling pump

10524.0.54

PHC ECI Cooling Pump - Undervoltage

ECI cooling pump under voltage, voltage is lower than 18.0V

-Check PHC-3 input voltage is higher than 18.0V

-Replace ECI cooling pump

10524.0.55

PHC ECI Cooling Pump - Overtemp

ECI cooling pump temperature higher than 100°C (212°F)

-Check ECI cooling pump for damages

-Replace ECI cooling pump

10524.0.100 PHC ECI Cooling Pump - No Communication

No communication with ECI cooling pump

-Check if ECI pump is connected

-Check wires to ECI pump for open circuits

-Check power supply cooling pump

-Wrong cooling pump confi gured, parameter 0301

10524.0.205 PHC ECI Cooling Pump - HW FAULT

ECI cooling pump hardware fault

-Replace ECI cooling pump

10526.0.0

PHC ECI Cooling Pump Blocked - -

ECI cooling pump is blocked

-Reset fault and if fault reappears, cooling pump need service or 

replacement.

-Check pump inlet for obstacles

10527.1.0

PHC VFD Not Ready Instance 1 -

VFD not ready

-VFD external run enable/power available signal is lost.

10528.1.10

PHC VFD ABB Parameter Instance 1 Level Low ABB ACS550 parameter values 2001 or 2002 cannot be a 

negative value.

-Check ABB ACS550 parameter 2001 and 2002.

10529.0.19

PHC ECI Cooling Pump Speed - Under Limit

ECI pump motor speed under limit, below 100rpm

-Check hose for dirt

-Check pump inlet for obstacles

10530.0.201 PHC PTO ENGINE INSTANCE - INIT FAIL

Parameter 1011-PTO ENGINE INSTANCE is not defi ned

-Set parameter 1011-PTO ENGINE INSTANCE

36000.1.24

ABB ACS550 Instance 1 Fault

ABB ACS550 fault

See ABB ACS550 drive for more details

36002.1.24

VACON Instance 1 Fault

VACON VFD Fault

See VACON drive for more details

36100.1.100 VFD Instance 1 No Communication

Lost communication with VFD

-VFD not powered up

-VFD communication cable not connected or incorrectly wired

36103.1.0

VFD IN LOCAL Instance 1 -

VFD in local mode

-Switch VFD to remote mode

PDC-301 Alarm Descriptions

EN

MC_0119

Fault Code

Description

Cause

Action

10600.0.208 SR150000 Fault - INTERLOCK

Retract Interlock

-Check if retract is depoyed.

-No communication with Retract Controller, check Retract Controller 

has power.

-Check PDC-301 and Restract Controller setup.

36100.1.24

VFD Instance 1 Fault

VFD faulted

-See VFD for more information

36100.1.100 VFD Instance 1 No Communication

PDC-301 has no MODBUS communication with VFD.

-Check communication cable with VFD

-Check if VFD has power

36101.1.200 VFD PMS Instance 1 Timeout

VFD is not ready within 60 after power reqest.

-Check if VFD has power

36101.1.204 VFD PMS Instance 1 SIGNAL LOST

Lost Power Management signal from VFD, VFD not avilable 

anymore.

-Check VFD for more information.

36103.1.0

VFD IN LOCAL Instance 1 -

VFD in Local or Hand Mode

-Change mode in VFD panel.

 13

6032

3

2019

-

SEP user manual

Summary of Contents for SH SERIES

Page 1: ... SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com Document id Revision Date 6032 3 SH SERIES HYDRAULIC USER MANUAL To download your language go to www side power com K e e p t h i s m a n u a l o n b o a r d 2019 ...

Page 2: ...VE 2013 53 EU DIRECTIVE 2014 30 EU DIRECTIVE 2014 35 EU MC_0020 Important User Considerations and Precautions 3 User Manual Thruster Operation 4 Control Panel 5 Proportional Thruster Display 6 Proportional Thruster Display Symbols 6 HOLD Function 7 Calibration 7 Warning Signals When Using HOLD Function 7 8 MENU System 8 Alarm Descriptions 9 10 Maintenance 11 12 Troubleshooting 13 Checklist 14 Spar...

Page 3: ...wer switch for the thruster Make sure that only one control is used at the same time If two panels are operated in opposite directions at the same time the thruster will not run If both are operated in the same direction the thruster will run in this direction If the thruster is not performing or functioning as usual the cause must be found and corrected as soon as possible to avoid causing any ot...

Page 4: ...bow is in the desired position NB The boat will continue to move after disengaging the thruster control How to use a single stern thruster Due to space limitations a vessel may only have a stern thruster In this case the stern thruster is used in the same way as a single bow thruster for moving the boat s stern Follow the above instruction for operation use How to use a combined bow and stern thru...

Page 5: ...trol panel or cancel or go back in the menu system or to mute internal alarm buzzer Information display see following pages for details Emergency stop button Speed control joystick for bow thruster Speed control joystick for stern thruster Control panel example Control panel example Control panel example Control panel example Activating the stern thruster Activating both bow and stern thruster to ...

Page 6: ...ly shown in a dual stern thruster setup Battery indicator will be shown here in a single DC electric stern thruster setup BOW STERN BOW STB STERN STB Examples of display view for different panels applications PJC211 DC Electric Bow thruster PJC221 Hydraulic Bow thruster PJC221 AC Electric Bow thruster PJC212 DC Electric Bow thruster DC Electric Stern Thruster PJC222 Hydraulic Bow thruster Hydraulic...

Page 7: ... 24V thrusters Motor temperature indicator From 70 C 158 F to 130 C 266 F Symbol shown when a DC Thruster is used in a dual bow or dual stern setup Proportional Thruster Display Symbols EN MC_0053 Thrust power and direction Bow thruster s Input from bow joystick on this panel The thrust indicator will be shown in this position on a single joystick panel if the thruster is defined as a bow thruster ...

Page 8: ...cklight in display and continous short beeps Voltage below 8 5V 15V 12V 24V system Temperature above 110 o C 230 o F None 4 Red backlight in display and continous short beeps If one or more of the thrusters enters an alarm state Voltage below 8 0V 12 0V 12V 24V system or temperature above 120 o C 248 o F HOLD function are canselled and both thrusters will stop Temperature must drop below 110 C 230...

Page 9: ...gs Language English Backlight Level 5 Backlight Night Color Green Backlight Nightlevel 1 Timer Auto Off 05 min Hold Calibration 70 Bow and Stern All system devices will be erased from memory Setup procedure must be followed to reconfigure the system STABILIZER STABILIZER Shown only for yachts equipped with a Side Power Stabilizer system Press the button below to edit the selected parameter ON OFF wi...

Page 10: ...rror 2 3 Motor relay fault Turn off thruster battery main switch Thruster must be serviced by author ized personel 8 Critical Error 2 3 PPC output fail PPC must be sent for service 9 Low Motor Current 2 3 Thruster uses no power Check thruster connections or motor dead 10 Motor Contactor 2 3 No current on motor relay coil Check motor relay connections short circuit or relay dead 11 System Error 2 3...

Page 11: ...Yes 1 2 3 Any Stabilizer alarm See stabilizer panel for more info 28 AC Motor Overtemp Yes 1 2 3 Hydraulic AC motor power pack over temp Higher than 120 C 248 F Stop running and wait for tempera ture to drop 29 AC Motor Sensor Fail 2 3 Hydraulic AC motor power pack temp sensor open curicuit Check sensor cables 30 Temperature Warning Yes 2 3 High temperature warning Warns that the motor temperature...

Page 12: ... Wires shorted or sensor defective check wiring sensor Replace sensor 10505 0 13 PHC AI 2 Open Circuit Analog Input 2 4 20mA sensor open circuit Sensor not connected or wire break 10505 0 16 PHC AI 2 Short Circuit Analog Input 2 4 20mA sensor short circuit Wires shorted or sensor defective check wiring sensor Replace sensor 10508 0 13 PHC DOUT AC PUMP UNLOAD Open Circuit AC Pump Unload valve open ...

Page 13: ...temp ECI cooling pump temperature higher than 100 C 212 F Check ECI cooling pump for damages Replace ECI cooling pump 10524 0 100 PHC ECI Cooling Pump No Communication No communication with ECI cooling pump Check if ECI pump is connected Check wires to ECI pump for open circuits Check power supply cooling pump Wrong cooling pump configured parameter 0301 10524 0 205 PHC ECI Cooling Pump HW FAULT EC...

Page 14: ... the boat Consult your dealer for information on how to do this Drain oil after first 50 hours of runtime then with 500 hours runtime intervals Refill with GL 5 gear oil if needed Change the gear oil a minimum of every second year Check the gear oil quality in the guardhouse every time the boat is out of the water If there is a problem with your Ignition Protected stern thruster please contact your ...

Page 15: ...eg Pre filled 6 Propeller 7 Anode 8 Drive pin 9 Washer 10 Lock Nut 11 Fastening Screw for anode 12 Oil drain screw 13 Shaft Key 14 Anode pins SH 100 160 240 SH 320 SH 420 550 SH 700 1000 1400 11 13 11 11 10 10 10 9 9 9 8 8 7 7 7 7 7 7 6 6 6 6 6 6 5 5 5 5 5 5 4 4 4 3 3 3 2 2 2 1 1 1 11 14 12 12 13 10 9 7 7 6 6 5 5 4 3 2 1 ...

Page 16: ...signs of water try to fi nd the source and eliminate it Paint the propeller and gear leg with antifouling batteries are in good condition All electrical connections are clean and fastened fi rmly Check the drive shaft in the retract mechanism is lubricated Check for excess movement in the break away rings securing the actuator Change the zinc anode Check oil in the oil reservoir REPLACE EVERY 2 YEAR...

Page 17: ...ing equipment supplier that the installation instructions of the Installation and Operation Manual have been complied with and that the defect remains e warranty service shall be performed only by the Warrantor or an authorized Service Centre and any attempt to remedy the defect by anyone else shall render this warranty void 5 There shall be no warranty for defects or damages caused by faulty inst...

Page 18: ...MC_0037 Notes EN 18 6032 3 2019 SEP user manual ...

Page 19: ...MC_0037 Notes EN 19 6032 3 2019 SEP user manual ...

Page 20: ...MC_0037 Notes EN 20 6032 3 2019 SEP user manual ...

Page 21: ...MC_0037 Notes EN 21 6032 3 2019 SEP user manual ...

Page 22: ...MC_0037 Notes EN 22 6032 3 2019 SEP user manual ...

Page 23: ... future service and repair assistance To find additional product information search the serial number attached in this manual below or from the sticker on the motor installed in your vessel MC_0080 MC_0080 Please refer to the graphic for special considerations relating to your model IMPORTANT To register your product go to www side power com MG_0142 Sleipner Motor IDENTIFICATION LABELS User Manual ...

Page 24: ...ocument was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any possi ble differences between product and document ...

Reviews: