The info selection is a service screen. Choose the Info screen if
you wish to check your system. When in this screen you will be
able to run the thrusters individually with the joysticks or simul-
taneously with the “Hold” function.
You will be able to see two screens by pressing the “more” button
1st screen : Control panel info:
- Firmware and Hardware version
- Serial number
- S-link voltage
2nd screen: Bow thruster information
- Motor temperature
- Speed controller (PPC800) temperature
- Actual voltage
- Thrust percentage it is running at
- Current consumption & watt at present.
More: Changes to next information page
Cancel: Returns to main menu
SETUP
SCAN SYSTEM
After selecting “SCAN SYSTEM” the display shows “SCANNING
SYSTEM PLEASE WAIT!” for a few seconds while the panel is
scanning the S-link bus for attached equipment. This scan can
take up to 15 seconds.
After a completed system scan, the thruster with its associated
AMS will be shown. Use the joystick to toggle between bow and
stern thruster information.
Scan: Re-Scan the S-link bus
Select: Select thruster. Selected thruster will be highlighted and
can be run with the designated joystick to confirm its
location
Move: Moves the selected thruster assignment from bow to
stern/stern to bow
OK:
Saves changes and returns to SETUP-menu
Any changes made will be relayed to all other installed panels
RADIO REMOTE SETUP
Adjusts the amount of thrust which the ON/OFF remote control
will run at. Use joysticks to adjust applied thrust
OK:
Saves changes and returns to “SETUP”-menu
Cancel: Returns to “SETUP”-menu without saving changes
Any changes made will be relayed to 8730 INTERFACE units with
Firmware 1.203 or newer